Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switch Device built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Thermopane®" external double-glazed windowsMade of lacquered sheet steel, CFC-free polyurethane insulation.AISI 304 stainless steel display, exposure depth 570 mm, height 790mm3 adjustable intermediate "tempered" glass shelves (1x 300 + 2x 350 mm), supporting structure in stainless steel AISI 304Service side 2 double-glazed "Thermopane®" sliding doors, vertical joints.Heating by electric resistancesMechanical thermostat, On/Off switchDevice built in compliance with the standards (CE) in force.
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...