Production capacity 200 baskets/hourPre-wash + Washing + rinsing2 forward speedsPredisposed for left-hand entryLoad height 440 mmWater pressure reducer, equipped with pressure gauge.Made in AISI 304 Stainless Steel, of 12/10mm and 30/10mm thick, double skin thermal and acoustic insulation (-60db) with adjustable stainless steel feet.Linear or angular configuration with left and right entry/feed tablesTraction system with parallel stainless steel bars.Automatic advance system with 3...
%
%
%
%
Production capacity 200 baskets/hourWashing + rinsing3 forward speedsPredisposed for left-hand entryLoad height 440 mmAnti-pollution device type AB "Break Tank"Flushing pump as standard (atmospheric boiler).Made of AISI 304 stainless steel, between 12/10 mm and30/10 mm thick, double-walled for better insulationthermal and acoustic (- 60 db), adjustable stainless steel feet.Linear or angular layout with left or right input.Traction system with parallel bars made of steelstainless...
%
%
%
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...