Ribbon saw in stainless steel of 1550 mm. designed for cutting meat and frozen fish.Maximum cutting height 170 mm.Engine 1hp, tension regulator of the ribbon.Frame made of anodised aluminium.Security microswitch, engine brake, low tension operators.Equipped with a push-button, calibration plate in stainless steel AISI 304.
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
Tank diameter 600 mm, depth 420 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 600 mm, depth 540 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 760 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (25/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 960 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (30/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 1060 mm, depth 600 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (40/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 400 mm, depth 465 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (15/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick) Made of AISI 304 stainless steel, stainless steel base. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of 304 stainless steel, bottom made of...
%
Tank diameter 760 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (25/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 960, depth 500mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (30/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 600 mm, depth 420 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 600 mm, depth 540 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 760 mm, depth 500 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (25/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 960 mm, depth 500 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (30/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 1060 mm, depth 600 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (40/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 400 mm, depth 465 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (15/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, stainless steel base. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of 304 stainless steel, bottom made of...