Production capacity 200 baskets/hourPre-wash + Washing + rinsing2 forward speedsPredisposed for left-hand entryLoad height 440 mmWater pressure reducer, equipped with pressure gauge.Made in AISI 304 Stainless Steel, of 12/10mm and 30/10mm thick, double skin thermal and acoustic insulation (-60db) with adjustable stainless steel feet.Linear or angular configuration with left and right entry/feed tablesTraction system with parallel stainless steel bars.Automatic advance system with 3...
%
%
%
%
Production capacity 200 baskets/hourWashing + rinsing3 forward speedsPredisposed for left-hand entryLoad height 440 mmAnti-pollution device type AB "Break Tank"Flushing pump as standard (atmospheric boiler).Made of AISI 304 stainless steel, between 12/10 mm and30/10 mm thick, double-walled for better insulationthermal and acoustic (- 60 db), adjustable stainless steel feet.Linear or angular layout with left or right input.Traction system with parallel bars made of steelstainless...
%
%
%
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Mechanical controls, mats manipulated by a lever arm.Base mounted version, 4 wheels, 2 fixed, 2 swivel wheels with brakes.Manual and pedal controls.Removable top flour bin.Removable tables.Lifting of safety grids assisted by pistons.1 speed1400x600 mm side tables (can be lifted or dismantled)Cylinder length 600 mmOpening of the cylinders from 0 - 50 mm, rolling diameter 80 mm.Travel speed 35 metres/minuteClosed overall dimensions 620x1060xh2300Standard: 2 stainless steel harvesting terminals,...
%
Mechanical controls, mats manipulated by a lever arm.Base mounted version, 4 wheels, 2 fixed, 2 swivel wheels with brakes.Manual and pedal controls.Removable top flour bin.Removable tables.Lifting of safety grids assisted by pistons.Variable speed (10 rpm to 60 rpm), with Inverter.1400x600 mm side tables (can be lifted or dismantled)Cylinder length 600 mmOpening of the cylinders from 0 - 50 mm, rolling diameter 80 mm.Travel speed 35 metres/minuteClosed overall dimensions...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
1 temperature (+1° +18°C).Inside dimensions: 470x440xh1555 mm.Load capacity: 118 wine bottles (0,75 l.).Included: 6 shelves 490x360 mm (in wood). Full door, reversible, closure by magnetic joint.Closure with keys.Electronic thermostat.Digital thermometer.Built-in compressor unit, climatic class 4 (30°C & 55% RH).Ventilated evaporator, refrigerant R600a.Automatic defrosting with self-evaporation of condensate.Interior in ABS (black), exterior in lacquered steel sheet (black).Insulation in...
%