Production capacity 200 baskets/hourPre-wash + Washing + rinsing2 forward speedsPredisposed for left-hand entryLoad height 440 mmWater pressure reducer, equipped with pressure gauge.Made in AISI 304 Stainless Steel, of 12/10mm and 30/10mm thick, double skin thermal and acoustic insulation (-60db) with adjustable stainless steel feet.Linear or angular configuration with left and right entry/feed tablesTraction system with parallel stainless steel bars.Automatic advance system with 3...
%
%
%
%
Production capacity 200 baskets/hourWashing + rinsing3 forward speedsPredisposed for left-hand entryLoad height 440 mmAnti-pollution device type AB "Break Tank"Flushing pump as standard (atmospheric boiler).Made of AISI 304 stainless steel, between 12/10 mm and30/10 mm thick, double-walled for better insulationthermal and acoustic (- 60 db), adjustable stainless steel feet.Linear or angular layout with left or right input.Traction system with parallel bars made of steelstainless...
%
%
%
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Version 2 drawers GN 1/1max. load Height 320 mm2 ventilated evaporators "treaty".6 adjustable stainless steel feet. Monocoque designInside and outside (top included) manufactured in stainless steel AISI 441 (also the back).Stamped interior bottom, rounded angles and corners (without roughness).Drawers with ergonomic handle, on telescopic slides, "snap-fit" closure by magnetic joint (easy replacement without tools).Compressor unit climate class 4 (30°C Temperature & 55% Humidity), ), built...
%
Version 4 drawers GN 1/1 (max. load Height 300 mm).2 ventilated evaporators "treaty".8 adjustable stainless steel feet. Monocoque design.Inside and outside (top included) manufactured in stainless steel AISI 304 (also the back).Stamped interior bottom, rounded angles and corners (no rough edges).Drawers with ergonomic handles, on telescopic runners, closed by magnetic pressure seals (easy replacement, no tools required).Class 5 compressor unit (40°C Temperature & 40% Humidity), built into...