Fonctions :Possibility of inserting food having a temperature until 90° C.- Version NNC: 3 cycles personnalisables (software +3°C, hardware +3°C,maintenance), version BCC: 5 cycles personnalisables (software +3 or -18°C, hardware +3 or -18°C, maintenance), specific cycles for the ice cream.- Function CRUISE.- Function CCRT which considers the residual time remaining before the end of the cycle.- Function TURBO CCTC especially conceived for the continuously production.- Sensor with 3 probes...
%
Fonctions :Possibility of inserting food having a temperature until 90° C.- Version NNC: 3 cycles personnalisables (software +3°C, hardware +3°C,maintenance), version BCC: 5 cycles personnalisables (software +3 or -18°C, hardware +3 or -18°C, maintenance), specific cycles for the ice cream.- Function CRUISE.- Function CCRT which considers the residual time remaining before the end of the cycle.- Function TURBO CCTC especially conceived for the continuously production.- Sensor with 3 probes...
%
LENGTHWISE" cell for loading GN 1/3, 1/2, 2/3 and 1/1 plates.Load capacity: 6x GN1/1 or 5x 600x400mm.Production per cycle: 30Kg (+70° +3°) and 30Kg (+70° -18°).Chamber size: 505x705xh450mm.Core probe.Built-in compressor unit.NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm thick, stainless steel feet.Speaker: rounded corners and angles without roughness....
%
LENGTHWISE" cell for loading GN 1/3, 1/2, 2/3 and 1/1 plates.Load capacity: 10x GN1/1 or 8x 600x400mm.Production per cycle: 50Kg (+70° +3°) and 50Kg (+70° -18°).Chamber size: 505x705xh900mm.Core probe.Built-in compressor unit.NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm thick, stainless steel feet.Speaker: rounded corners and angles without roughness....
%
Cell for loading GN 2/1 (or GN 1/1).Load capacity: 10x GN2/1 or 8x 600x400mm.Production per cycle: 100Kg (+70° +3°) and 70Kg (+70° -18°).Chamber size: 670x843xh900mm.Core probe.Built-in compressor unit.NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm thick, stainless steel feet.Speaker: rounded corners and angles without roughness. Deep-drawn bottom that...
%
LENGTHWISE" cell for loading GN 1/3, 1/2, 2/3 and 1/1 plates.Load capacity: 20x GN1/1 or 16x 600x400mm.Production per cycle: 100Kg (+70° +3°) and 85Kg (+70° -18°).Chamber size: 525x705xh1453mm.Core probe.Compressor unit not included.Trolley & charger 600x400 EURONORM (on request ref: AC/2P2...)NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm thick,...
%
Cell for loading plates GN 2/1 (or GN 1/1).Load capacity: 20x GN2/1 or 16x 600x400mm.Production per cycle: 200Kg (+70° +3°) and 170Kg (+70° -18°).Chamber size: 780x946xh1850mm.Cell delivered disassembled.Core probe.Compressor unit not included.Trolley & charger 600x400 EURONORM (on request ref: AC/2P2...)NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...