%
Flow of 30 liters/hour.Tap with gooseneck to fill in the glasses, immediate pulling. Copper evaporator following the norms (avoiding any bacteriological development).Direct expansion system (French norms).Equipped with a triple action filter (sediment, limestone, chlorine).Thermic unit (ambient T° +32°C).Refrigerant gas R290 .CFC-free polyurethane insulationPredisposed for connection at the cold water system and a discharge.Realization in stainless steel .The equipment is manufactured...
%
Flow from 35 liters/hours.Water outlet controlled by a solenoid valve operated by a stainless steel pedal.Tap with gooseneck to fill in the glasses, immediate pulling.Lifting tray, removable bowl for better cleaning. Copper evaporator following the norms (avoiding any bacteriological development).Direct expansion system (French norms).Equipped with a triple action filter (sediment, limestone, chlorine).Thermic unit (ambient T° +32°C).Refrigerant gas R290 .CFC-free polyurethane...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
Inside volume: 300 liters.Inside dimensions: 1257x345xh720 mm.Load capacity: 380 cans (33 cl) or 218 bottles (33 cl).3 slinding doors (automatic closing), with door locking device for loading.Included: 6 grids 395x300 mm.Cooling R290. Glass door(s), double glazing, "Thermopane"®.Closure by keys.Interior lighting type LED.Included: for each door, 2 adjustable shelves and removable height.Built-in compressor unit climatic class 4 (30°C & 55% HR).Sound level 45 db (A).Electronic regulation,...
%
Flow of 30 liters/hour.Tap with gooseneck to fill in the glasses, immediate pulling.Copper evaporator following the norms (avoiding any bacteriological development).Direct expansion system (French norms).Equipped with a triple action filter (sediment, limestone, chlorine).Thermic unit (ambient T° +32°C).Refrigerant gas R134a.CFC-free polyurethane insulationPredisposed for connection at the cold water system and a discharge.Realization in stainless steel .The equipment is manufactured...
%
%
%
Energy efficiency class: B.Variable-speed compressor.Inside volume: 300 liters.Inside dimensions: 1257x345xh720 mm.Load capacity: 380 cans (33 cl) or 218 bottles (33 cl).3 slinding doors (automatic closing), with door locking device for loading.Included: 6 grids 395x300 mm.Cooling R290. Low energy consumption components.Glass door(s), double-glazed "Thermopane".Locking device with keys.Interior LED lighting.Included: For each door, 2 removable and height-adjustable grids.Built-in compressor...