For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with belt drive, 2 speed levels.3 double filtering.
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with belt drive, 2 speed levels.3 double filtering.
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with belt drive, 2 speed levels.3 double filtering.
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with belt drive, 2 speed levels.3 double filtering.
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
Profile frame in aluminum.Panels with double isolated walls.Lateral inspection.Ventilator with belt drive, 2 speed levels.3 double filtering.
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
Profile frame in aluminum.Panels with double isolated walls.Lateral inspection.Ventilator with belt drive, 2 speed levels.3 double filtering.