- Water condenser.- Versatile pasto turbine cookers for cooking, tempering, pasteurizing and freezing all mixtures or pastes. - Multilingual display with 14 pre-programmed cycles and 10 programmable production cycles. - Different heat treatments are carried out in a single cylinder, avoiding any handling or transfer. - Possibility of slow, fast or intermittent agitation. - Automatic memory of the last cycle. - Mix per cycle: 30/60 litres. - Cycle time: 90/130 min.
%
%
- Air condenser.- Multifunctional pastoturbine for mixing, heating, pasteurizing, cooling and lashing all creams, sauces and mixes. - Adjustable times and temperatures. - Intuitive and easy to use "Touch Screen" control panel (18 pre-installed cycles: 9 for ice cream, 7 for pastry, 2 for gastronomy) with the possibility of inserting new recipes. - Manual or fully automatic cycle. - Pasteurization and lashing are carried out in a single cylinder, avoiding any handling or transfer. - Vertical...
%
- Air condenser.- Multifunctional pastoturbine for mixing, heating, pasteurizing, cooling and lashing all creams, sauces and mixes. - Adjustable times and temperatures. - Intuitive and easy to use "Touch Screen" control panel (18 pre-installed cycles: 9 for ice cream, 7 for pastry, 2 for gastronomy) with the possibility of inserting new recipes. - Manual or fully automatic cycle. - Pasteurization and lashing are carried out in a single cylinder, avoiding any handling or transfer. - Vertical...
%
- Water condenser.- Multifunctional pastoturbine for mixing, heating, pasteurizing, cooling and lashing all creams, sauces and mixes. - Adjustable times and temperatures. - Intuitive and easy to use "Touch Screen" control panel (18 pre-installed cycles: 9 for ice cream, 7 for pastry, 2 for gastronomy) with the possibility of inserting new recipes. - Manual or fully automatic cycle. - Pasteurization and lashing are carried out in a single cylinder, avoiding any handling or transfer. - Vertical...
%
- Water condenser.- Multifunctional pastoturbine for mixing, heating, pasteurizing, cooling and lashing all creams, sauces and mixes. - Adjustable times and temperatures. - Intuitive and easy to use "Touch Screen" control panel (18 pre-installed cycles: 9 for ice cream, 7 for pastry, 2 for gastronomy) with the possibility of inserting new recipes. - Manual or fully automatic cycle. - Pasteurization and lashing are carried out in a single cylinder, avoiding any handling or transfer. - Vertical...
%
- Air condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 30/60 litres. - Cycle time: 100/120 min.
%
- Air condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 30/60 litres. - Cycle time: 100/120 min.
%
- Water condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 30/60 litres. - Cycle time: 100/120 min.
%
- Water condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 30/60 litres. - Cycle time: 100/120 min.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
Chambrer 720x1080xh150 mm (7,8 kW)6 pizzas ofdiam. 350 mm (or) 2 pizzas of diam. 500 mm2 ovens superposable (6+6)Chamber in stainless steel, refractory stone floor.Electric blowhole "oura" internal lighting, for smokes-steam.Inside lightning recessed "high temperature"."Counterbalanced" door, "panoramic" window in securit glass.Heating through armored resistances in stainless steel, put under the base and on the oven vault, arch in stainless steel avoiding the temperature dropping when...
%
%
Chamber: 1080x720xh185 mm (18,5 kW), 6 pizzas diam. 350 mm (or) 2 pizzas diam. 500 mmProduction capacity: 48 to 54 pizzas /H (Diam. 350mm) or 16 to 18 pizzas /H (Diam. 500mm)2 stackable ovens (6+6) Stainless steel chamber, refractory stone base, thick rock wool insulation "Oura" for the evacuation of smoke and steamDouble recessed interior lighting "high T°".Door return by spring, stainless steel handle on the whole length of the door, "panoramic" safety glass window lined with a protective...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...