- Water condenser.- Versatile pasto turbine cookers for cooking, tempering, pasteurizing and freezing all mixtures or pastes. - Multilingual display with 14 pre-programmed cycles and 10 programmable production cycles. - Different heat treatments are carried out in a single cylinder, avoiding any handling or transfer. - Possibility of slow, fast or intermittent agitation. - Automatic memory of the last cycle. - Mix per cycle: 30/60 litres. - Cycle time: 90/130 min.
%
%
- Air condenser.- Multifunctional pastoturbine for mixing, heating, pasteurizing, cooling and lashing all creams, sauces and mixes. - Adjustable times and temperatures. - Intuitive and easy to use "Touch Screen" control panel (18 pre-installed cycles: 9 for ice cream, 7 for pastry, 2 for gastronomy) with the possibility of inserting new recipes. - Manual or fully automatic cycle. - Pasteurization and lashing are carried out in a single cylinder, avoiding any handling or transfer. - Vertical...
%
- Air condenser.- Multifunctional pastoturbine for mixing, heating, pasteurizing, cooling and lashing all creams, sauces and mixes. - Adjustable times and temperatures. - Intuitive and easy to use "Touch Screen" control panel (18 pre-installed cycles: 9 for ice cream, 7 for pastry, 2 for gastronomy) with the possibility of inserting new recipes. - Manual or fully automatic cycle. - Pasteurization and lashing are carried out in a single cylinder, avoiding any handling or transfer. - Vertical...
%
- Water condenser.- Multifunctional pastoturbine for mixing, heating, pasteurizing, cooling and lashing all creams, sauces and mixes. - Adjustable times and temperatures. - Intuitive and easy to use "Touch Screen" control panel (18 pre-installed cycles: 9 for ice cream, 7 for pastry, 2 for gastronomy) with the possibility of inserting new recipes. - Manual or fully automatic cycle. - Pasteurization and lashing are carried out in a single cylinder, avoiding any handling or transfer. - Vertical...
%
- Water condenser.- Multifunctional pastoturbine for mixing, heating, pasteurizing, cooling and lashing all creams, sauces and mixes. - Adjustable times and temperatures. - Intuitive and easy to use "Touch Screen" control panel (18 pre-installed cycles: 9 for ice cream, 7 for pastry, 2 for gastronomy) with the possibility of inserting new recipes. - Manual or fully automatic cycle. - Pasteurization and lashing are carried out in a single cylinder, avoiding any handling or transfer. - Vertical...
%
- Air condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 30/60 litres. - Cycle time: 100/120 min.
%
- Air condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 30/60 litres. - Cycle time: 100/120 min.
%
- Water condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 30/60 litres. - Cycle time: 100/120 min.
%
- Water condenser.- Automatic pasteurizer for high and low pasteurization. - Transparent cover. - Faucet has an integrated cleaning system. - Intelligent memory that allows to repeat, if necessary, the pasteurization cycle. - Mix per cycle: 30/60 litres. - Cycle time: 100/120 min.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
- Water condenser- Vertical turbine with automatic extraction.- Minimum mixing capacity 4 lit. and maximum 8 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis. - Cycle time: 8/12 min. - Hourly production: 60 litres.NB: mainly for cold work.
%
Charging height glasses 300 mm 30 baskets/hour,120-second cycle.Rotating wash and rinse arms (upper and lower).Self cleaning sprinklers.Tank, rounded edges (8 Lit., 0,6 kW).Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless steel AISI 304.Standard: 2 baskets,...
%
For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.