For engine ventilator of type:10/10/0,75 - 10/10/1,1 - 10/10/1,5 - 12/12/1,5 - 12/12/2,2Fuses of protection for the safety of the engine.Compound casket of:* Switch one / off ( 2 speeds) coupled with a warning light,* Switch one / off, lighting coupled with a warning light,* Lock with key.- Metallic casket seals IP55.
%
For engine ventilator of type:10/10/0,75 - 10/10/1,1 - 10/10/1,5 - 12/12/1,5 - 12/12/2,2Fuses of protection for the safety of the engine.Compound casket of:* Switch one / off ( 2 speeds) coupled with a warning light,* Switch one / off, lighting coupled with a warning light,* Lock with key.- Metallic casket seals IP55.
%
For engine ventilator of type:10/10/0,75 - 10/10/1,1 - 10/10/1,5 - 12/12/1,5 - 12/12/2,2Fuses of protection for the safety of the engine.Compound casket of:* Switch one / off ( 2 speeds) coupled with a warning light,* Switch one / off, lighting coupled with a warning light,* Lock with key.- Metallic casket seals IP55.
%
%
For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
Tank diameter 600 mm, depth 420 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, adjustable stainless steel feet. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of stainless steel 304,...
%
Tank diameter 600 mm, depth 540 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, adjustable stainless steel feet. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of stainless steel 304,...
%
Tank diameter 760 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (25/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, adjustable stainless steel feet. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of stainless steel 304,...
%
Tank diameter 960 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (30/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, adjustable stainless steel feet. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of stainless steel 304,...
%
Tank diameter 1060 mm, depth 600 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (40/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, adjustable stainless steel feet. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of stainless steel 304,...
%
Tank diameter 600 mm, depth 420 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, adjustable stainless steel feet. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of stainless steel 304,...
%
Tank diameter 600 mm, depth 540 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, adjustable stainless steel feet. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of stainless steel 304,...
%
Tank diameter 760 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (25/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, adjustable stainless steel feet. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of stainless steel 304,...