%
With adapter for hamburger device.Frame in stainless steel AISI 304.Ventilated motor (IP 55) designed for intensive use.Gear drive in oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, tool-free connection (fastening by means of a lever), completely dismountable, easy and hygienic maintenance.Upper hopper in AISI 304 stainless steel (removable), with "square" inlet, for a very quick second passage.Low-voltage 24 V controls, IP 67...
%
With adapter for hamburger device.Frame in stainless steel AISI 304.Ventilated motor (IP 55) designed for intensive use.Gear drive in oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, tool-free connection (fastening by means of a lever), completely dismountable, easy and hygienic maintenance.Upper hopper in AISI 304 stainless steel (removable), with "square" inlet, for a very quick second passage. Low-voltage 24 V controls, IP 67...
%
With adapter for hamburger device.Designed for high productivity.AISI 304 stainless steel chassis (washable with water jet), standard on stainless steel base with wheels fitted with brakes.Ventilated motor (IP 55 ) designed for intensive use.Driven by hermetically sealed gear motor, under oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, quick bayonet fixing device (no tools required), completely dismountable, easy and hygienic...
%
With adapter for hamburger device.Designed for high productivity.AISI 304 stainless steel chassis (washable with water jet), standard on stainless steel base with wheels fitted with brakes.Ventilated motor (IP 55 ) designed for intensive use.Driven by hermetically sealed gear motor, under oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, quick bayonet fixing device (no tools required), completely dismountable, easy and hygienic...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...