Production capacity 100 kg (160 Lt)Flour capacity 66 kg2 speeds, automatically adjustable (Spiral: 1st Speed 112 rpm and 2nd Speed 230 rpm) & (Tank: 16 rpm)2 electronic timers, for the automatic management of each speed.2 independent motors, one for the tank and one for the spiralDevice for pulse rotation of the tank and reversal of the direction of rotation of the tank.Tank Ø 700xh410 mm Control panel, low voltage 24 V. (IP55).Motors with pulley transmissions.Emergency stop button type...
%
Production capacity 130 kg (200 Lt)Flour capacity 86 kg2 speeds, automatically adjustable (Spiral: 1st Speed 112 rpm and 2nd Speed 230 rpm) & (Tank: 16 rpm)2 electronic timers, for the automatic management of each speed.2 independent motors, one for the tank and one for the spiralDevice for pulse rotation of the tank and reversal of the direction of rotation of the tank.Tank Ø 800xh430 mm Control panel, low voltage 24 V. (IP55).Motors with pulley transmissions.Emergency stop button type...
%
Production capacity 160 kg (250 Lt)Flour capacity 106 kg2 speeds, automatically adjustable (Spiral: 1st Speed 111 rpm and 2nd Speed 223 rpm) & (Tank: 15 rpm)2 electronic timers, for the automatic management of each speed.2 independent motors, one for the tank and one for the spiralDevice for pulse rotation of the tank and reversal of the direction of rotation of the tank.Tank Ø 900xh430 mm Control panel, low voltage 24 V. (IP55).Motors with pulley transmissions.Emergency stop button type...
%
Production capacity 200 kg (290 Lt)Flour capacity 133 kg2 speeds, automatically adjustable (Spiral: 1st Speed 111 rpm and 2nd Speed 223 rpm) & (Tank: 15 rpm)2 electronic timers, for the automatic management of each speed.2 independent motors, one for the tank and one for the spiralDevice for pulse rotation of the tank and reversal of the direction of rotation of the tank.Tank Ø 900xh470 mm Control panel, low voltage 24 V. (IP55).Motors with pulley transmissions.Emergency stop button type...
%
Production capacity 250 kg (390Lt)Flour capacity 166 kg2 speeds, automatically adjustable (Spiral: 1st Speed 114 rpm and 2nd Speed 228 rpm) & (Tank: 15 rpm)2 electronic timers, for the automatic management of each speed.2 independent motors, one for the tank and one for the spiralDevice for pulse rotation of the tank and reversal of the direction of rotation of the tank.Tank Ø 1000xh470 mm Control panel, low voltage 24 V. (IP55).Motors with pulley transmissions.Emergency stop button type...
%
Production capacity 40 kg (80 Lt)Flour capacity 25 kg2 speeds, automatically adjustable (Spiral: 1st Speed 112 rpm and 2nd Speed 224 rpm) & (Tank: 1st Speed 14 rpm and 2nd Speed 28 rpm)2 electronic timers, for the automatic management of each speed.Tank Ø 530xh320 mm Control panel, low voltage 24V. (IP55).Motor with pulley transmissions.Emergency stop button type "punch".Frame in epoxy painted steel, very thick.Spiral tank, tool shaft and dividing share are made of thick AISI 304...
%
Production capacity 60 kg (100 Lt)Flour capacity 35 kg2 speeds, automatically adjustable (Spiral: 1st Speed 112 rpm and 2nd Speed 224 rpm) & (Tank: 1st Speed 14 rpm and 2nd Speed 28 rpm)2 electronic timers, for the automatic management of each speed.Tank Ø 580xh360 mm Control panel, low voltage 24V. (IP55).Motor with pulley transmissions.Emergency stop button type "punch".Frame in epoxy painted steel, very thick.Spiral tank, tool shaft and dividing share are made of thick AISI 304...
%
Production capacity 60 kg (100 Lt)Flour capacity 40 kg2 speeds, automatically adjustable (Spiral: 1st Speed 98 rpm and 2nd Speed 198 rpm) & (Tank: 21 rpm)2 electronic timers, for the automatic management of each speed.2 independent motors, one for the tank and one for the spiralDevice for pulse rotation of the tank and reversal of the direction of rotation of the tank.Tank Ø 600xh360 mm Control panel, low voltage 24 V. (IP55).Motors with pulley transmissions.Emergency stop button type...
%
Production capacity 80 kg (130 Lt)Flour capacity 53 kg2 speeds, automatically adjustable (Spiral: 1st Speed 112 rpm and 2nd Speed 230 rpm) & (Tank: 16 rpm)2 electronic timers, for the automatic management of each speed.2 independent motors, one for the tank and one for the spiralDevice for pulse rotation of the tank and reversal of the direction of rotation of the tank.Tank Ø 700xh370 mm Control panel, low voltage 24 V. (IP55).Motors with pulley transmissions.Emergency stop button type...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...