2 labyrinths filters ANTI GREASE (2x 400x500 mm) Model with built-in centrifugal fan "watertight" (IP55) incorporated (central position, in vertical).Designed in stainless steel AISI 441, assembly by points welding.Filters anti-fat has stainless steel labyrinths AISI 430.Peripheral channel for the fat collection, fitted with a drainage tap.Built-in lighting (LED) waterproof (IP65), high temperature.Speed regulator built-in the frontal.
%
3 Filters ANTI-FAT labyrinths (2x 400x500 & 1x 500x500 mm) Model with built-in centrifugal fan "watertight" (IP55) (central position, in vertical).Designed in stainless steel AISI 441, assembly by points welding.Filters anti-fat has stainless steel labyrinths AISI 430.Peripheral channel for the fat collection, fitted with a drainage tap.Built-in lighting (LED) waterproof (IP65), high temperature.Speed regulator built-in the frontal.
%
4 Filters ANTI-FAT labyrinths (2x 400x500 & 2x 500x500 mm) Model with built-in centrifugal fan "watertight" (IP55) (central position, in vertical).Designed in stainless steel AISI 441, assembly by points welding.Filters anti-fat has stainless steel labyrinths AISI 430.Peripheral channel for the fat collection, fitted with a drainage tap.Built-in lighting (LED) waterproof (IP65), high temperature.Speed regulator built-in the frontal.
%
5 Filters ANTI-FAT labyrinths (2x 400x500 & 3x 500x500 mm) Model with built-in centrifugal fan "watertight" (IP55) (central position, in vertical).Designed in stainless steel AISI 441, assembly by points welding.Filters anti-fat has stainless steel labyrinths AISI 430.Peripheral channel for the fat collection, fitted with a drainage tap.Built-in lighting (LED) waterproof (IP65), high temperature.Speed regulator built-in the frontal.
%
Inside dimensions: 855x885xh1762.Big dimensions door: 855xh1810.Included: 2 grids in stainless steel tube (830x820 mm). Dismountable structure, locking of the panels by built-in "eccentric" hooks.Inside and outside realization in steel sheet (pre-painted), angles and corners without bumps.Stainless steel floor.Strong-built grids in stainless steel tube (20 mm) melted, stainless steel racks (anti-swinging).Reversible door, built-in handle (not outstanding), magnetic joint (easy replacement,...
%
Inside dimensions: 855x885xh1912.Big dimensions door: 855xh1960.Included: 3 grids in stainless steel tube (830x820 mm).Dismountable structure, locking of the panels by built-in "eccentric" hooks.Inside and outside realization in steel sheet (pre-painted), angles and corners without bumps.Stainless steel floor.Strong-built grids in stainless steel tube (20 mm) melted, stainless steel racks (anti-swinging).Reversible door, built-in handle (not outstanding), magnetic joint (easy replacement,...
%
Inside dimensions: 855x885xh1912.Big dimensions door: 855xh1960.Included: 3 grids in stainless steel tube (830x820 mm).Dismountable structure, locking of the panels by built-in "eccentric" hooks.Inside and outside realization in steel sheet (pre-painted), angles and corners without bumps.Stainless steel floor.Strong-built grids in stainless steel tube (20 mm) melted, stainless steel racks (anti-swinging).Reversible door, built-in handle (not outstanding), magnetic joint (easy replacement,...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
Monoblock unit, climate class 4 (30°C Temperature & 55% Humidity), equipped with 2 side handles (easily removable), ventilated condenser.Ventilated evaporator treated against the salt and the food acids.Refrigerant gas R455a.Programmable electronic regulator, display on front with blue LED.Automatic defrosting by reversal of cycle (programmable as one pleases), automatic evaporation of the condensate.Appliances are complied with the CE in force.