Internal dimensions 400x570xh90Pizza production/hour: Ø 150 mm "80 gr." = 130 pizzas, up to Ø 400 mm "585 gr." = 18 pizzas (baking time 3.5 to 4 minutes)4 stainless steel feet Interior and exterior construction in AISI 304 stainless steel, thermal insulation in ceramic fibre.Baking tunnel: electronic regulation of temperature and travel speed. Quick warm-up, easy access for maintenance.Maximum temperature 320°C.Electric heating: independent power regulation (high/low).Electronic "digital"...
%
Internal dimensions 400x570xh90Pizza production/hour: from Ø 150 mm "80 gr." = 130 pizzas, up to Ø 400 mm "585 gr." = 18 pizzas (cooking time 3.5 to 4 minutes)4 stainless steel feet Interior and exterior construction in AISI 304 stainless steel, thermal insulation in ceramic fibre.Baking tunnel: electronic regulation of temperature and travel speed. Quick warm-up, easy access for maintenance.Maximum temperature 320°C.Electric heating: independent power regulation (high/low).Electronic...
%
Internal dimensions 400x580xh95Pizza production/hour: Ø 150 mm "80 gr." = 145 pizzas, up to Ø 400 mm "585 gr." = 21 pizzas (baking time 3.5 to 4 minutes)On request: stainless steel base on castors (with brakes) (see SFTEV40/58-N).Possibility of stacking up to 3 ovens of the same model. Interior and exterior construction in AISI 304 stainless steel, thermal insulation in ceramic fibre.Baking tunnel: electronic regulation of temperature and travel speed. Quick warm-up, easy access for...
%
Internal dimensions 400x580xh95Pizza production/hour: from Ø 150 mm "80 gr." = 145 pizzas, up to Ø 400 mm "585 gr." = 21 pizzas (cooking time 3.5 to 4 minutes)On request: stainless steel base on swivel wheels (with brakes) (see SFTEV40/58-N).Possibility to stack up to 3 ovens of the same model Conctructed completely in stainless steel AISI 304, thermal isolation in ceramic fibre.Cooking tunnel: electronic regulation of the temperature and de velocity of heat transition. Quick reach of...
%
Internal dimensions 400x580xh95Pizza production/hour: from Ø 150 mm "80 gr." = 145 pizzas, up to Ø 400 mm "585 gr." = 21 pizzas (cooking time 3.5 to 4 minutes)On request: stainless steel base on swivel wheels (with brakes) (see SFTGV40/58-N).Possibility to stack up to 3 ovens of the same model Conctructed completely in stainless steel AISI 304, thermal isolation in ceramic fibre.Cooking tunnel: electronic regulation of the temperature and de velocity of heat transition. Quick reach of...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...