Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
With adapter for hamburger device.Frame in stainless steel AISI 304.Ventilated motor (IP 55) designed for intensive use.Gear drive in oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, tool-free connection (fastening by means of a lever), completely dismountable, easy and hygienic maintenance.Upper hopper in AISI 304 stainless steel (removable), with "square" inlet, for a very quick second passage.Low-voltage 24 V controls, IP 67...
%
With adapter for hamburger device.Frame in stainless steel AISI 304.Ventilated motor (IP 55) designed for intensive use.Gear drive in oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, tool-free connection (fastening by means of a lever), completely dismountable, easy and hygienic maintenance.Upper hopper in AISI 304 stainless steel (removable), with "square" inlet, for a very quick second passage. Low-voltage 24 V controls, IP 67...
%
With adapter for hamburger device.Designed for high productivity.AISI 304 stainless steel chassis (washable with water jet), standard on stainless steel base with wheels fitted with brakes.Ventilated motor (IP 55 ) designed for intensive use.Driven by hermetically sealed gear motor, under oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, quick bayonet fixing device (no tools required), completely dismountable, easy and hygienic...
%
With adapter for hamburger device.Designed for high productivity.AISI 304 stainless steel chassis (washable with water jet), standard on stainless steel base with wheels fitted with brakes.Ventilated motor (IP 55 ) designed for intensive use.Driven by hermetically sealed gear motor, under oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, quick bayonet fixing device (no tools required), completely dismountable, easy and hygienic...