Structure en acier inox AISI 304 18/10.Fond embouti, étanche, angles et coins arrondis.Couvercle ouvrable "Flip-Flop" de chaque côté.Boutoir "antichoc" périphérique.4 roues, dont 2 pivotantes.
%
With adapter for hamburger device.Frame in stainless steel AISI 304.Ventilated motor (IP 55) designed for intensive use.Gear drive in oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, tool-free connection (fastening by means of a lever), completely dismountable, easy and hygienic maintenance.Upper hopper in AISI 304 stainless steel (removable), with "square" inlet, for a very quick second passage.Low-voltage 24 V controls, IP 67...
%
With adapter for hamburger device.Frame in stainless steel AISI 304.Ventilated motor (IP 55) designed for intensive use.Gear drive in oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, tool-free connection (fastening by means of a lever), completely dismountable, easy and hygienic maintenance.Upper hopper in AISI 304 stainless steel (removable), with "square" inlet, for a very quick second passage. Low-voltage 24 V controls, IP 67...
%
With adapter for hamburger device.Designed for high productivity.AISI 304 stainless steel chassis (washable with water jet), standard on stainless steel base with wheels fitted with brakes.Ventilated motor (IP 55 ) designed for intensive use.Driven by hermetically sealed gear motor, under oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, quick bayonet fixing device (no tools required), completely dismountable, easy and hygienic...
%
With adapter for hamburger device.Designed for high productivity.AISI 304 stainless steel chassis (washable with water jet), standard on stainless steel base with wheels fitted with brakes.Ventilated motor (IP 55 ) designed for intensive use.Driven by hermetically sealed gear motor, under oil bath, double liquid protection (between mincer head and motor).Mincer head in AISI 304 stainless steel, quick bayonet fixing device (no tools required), completely dismountable, easy and hygienic...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...