For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
Independent selection of the 3 quartz ramps with 3 tubes: function toaster or salamander, without pre-heating, high output (400 toasts/hour).2 grids with thermal handles (1 with stainless steel closing).Realization in stainless steel.Floor space 510x320 mm.Heating by infrared "quartz" tubes.Quartz ramp selector, timer 15 min. with continuous position, tensioning warning light, heating warning light.Protection grids of the "quartz" tubes, dismountable (exclusive patent).Removable lower...
%
Independent selection of the 2 quartz ramps with 3 tubes: function toaster or salamander, without pre-heating, high output (200 toasts/hour).2 grids with thermal handles.Realization in stainless steel.Floor space 510x320 mm.Heating by infrared "quartz" tubes.Quartz ramp selector, timer 15 min. with continuous position, tensioning warning light, heating warning light.Protection grids of the "quartz" tubes, dismountable (exclusive patent).Removable lower collection tank.Lift-off of the back...
%
Glass doors (Thermopane®) 510 mm wide, useful passage 470xh737 mmLED lighting, on each doorInternal dimensions 2340x430x737 mm.2 rilsanized grids (450x430 mm) per door, adjustable, 3 interior storage (standing bottles) free height 737 mmLoad capacity in bottles 33cl = 588, in cans 33 cl = 840, 50 cl = 504Height without feet 820 mm4 adjustable feet (70 mm).Standard delivered with 4 central grids.Outside realization in Skinplate (color black), inside in Skinplate (color white), food guarantee...
%
Glass doors (Thermopane®) 510 mm wide, useful passage 470xh737 mmLED lighting, on each doorInternal dimensions 2340x430x737 mm.2 rilsanized grids (450x430 mm) per door, adjustable, 3 interior storage (standing bottles) free height 737 mmLoad capacity in bottles 33cl = 588, in cans 33 cl = 840, 50 cl = 504Height without feet 820 mm4 adjustable feet (70 mm).Standard delivered with 4 central grids.Outside cabinet made in stainless steel AISI 430 inner liner in stainless steel AISI 304.Interior...
%