%
For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
Realisation in anodized aluminium.Cylinder diameter 130 mm.
%
- Réfrigération statique / ventilée, température: -14° -24° - Caisson lumineux - Dimensions internes 470x440xh1545 mm- Gaz réfrigérant R290 - 6 grilles "évaporateur" 470x440 mm .- Réalisation extérieur en tôle plastifiée (blanche), intérieure en ABS moulé (blanc). - Eclairage interne, avec interrupteur On-Off - Thermostat mécanique, avec un thermomètre d'affichage analogique. - Porte double vitrage (Thermopane®) et chauffante, (non réversible), avec châssis en aluminium anodisé, poignée (très...
%
%
Static/ventilated refrigeration, temperature: -12° -22° .Light box.Internal dimensions 577x495xh1684 mmRefrigerant gas R2906 "evaporator" grids 577x500 mm. Exterior manufactured in plastic laminate (white), interior in "embossed" aluminium.Interior lighting, On-Off switchMechanical thermostat, with an analog display thermometer.Double glazing door (Thermopane®), (not reversible), with chassis in anodised aluminum, handle (very robust), door hinges with stop 100°, closing with magnetic...
%
Ventilated refrigeration, temperature: +2° +10° .Light box.Internal dimensions 585x495xh1515 mmRefrigerant gas R600aStandard: 6 adjustable grids 574x405 mm. Exterior manufactured in plastic laminate (white), interior in molded ABS (white).Interior lighting, On-Off switchMechanical thermostat, with an analog display thermometer.Double glazing door (Thermopane®), reversible, with chassis in anodised aluminum, handle (very robust), door hinges with stop 100°, closing with magnetic seal.Included...
%
Ventilated refrigeration, temperature: +2° +10° .Light box.Internal dimensions 585x495xh1515 mmRefrigerant gas R600aStandard: 6 adjustable grids 574x405 mm. Exterior manufactured in plastic laminate (white), interior in molded ABS (white).Interior lighting, On-Off switchMechanical thermostat, with an analog display thermometer.Double glazing door (Thermopane®), reversible, with chassis in anodised aluminum, handle (very robust), door hinges with stop 100°, closing with magnetic seal.Included...
%
%
Static/ventilated refrigeration, temperature: -14° -24°.Illuminated housingInternal dimensions 470x440xh1545 mmRefrigerant gas R2906 evaporator grids 470x440 mm. Exterior manufactured in plastic laminate (white), interior in molded ABS (white).Internal lighting, with On-Off switch.Mechanical thermostat, with analog display thermometer.Heated, double-glazed (Thermopane®) door (non-reversible), with anodized aluminum frame, sturdy handle and magnetic seal.Included key lock.Static evaporators...
%
Ventilated refrigeration, temperature: +2° +10° . Light box. Internal dimensions 585x495xh1515 mm Refrigerant gas R134a Standard: 6 adjustable grids 574x405 mm. Exterior manufactured in plastic laminate (white), interior in molded ABS (white). Interior lighting, On-Off switchMechanical thermostat, with an analog display thermometer. Double glazing door (Thermopane®), reversible, with chassis in anodised aluminum, handle (very robust), door hinges with stop 100°, closing with magnetic seal....