%
For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
Production 122 kg/24 h., capacity reserve 50 kg. "Paddle" system, particularly suitable for the hardest water conditions or bad quality water (algae, mud).Hollow ice cubes 20 g, ø 30 mm, h 25 mm.Ice cubes per cycle (15).Evaporator made of treaty cooper, dump ice cubes by reverse cycle "hot gas".No thermostat in the tank "too full", automatic interruption of the cycle, (the production stops when empty all the ice cubes stored in reserve).Inwardly sliding door, easy access ensuring strength and...
%
Production 22kg/24 h., capacity reserve 9 kg. "Palettes" system, particularly suitable for the hardest water conditions or bad quality water (algae, mud).Hollow ice cubes 20 g, ø 30 mm, h 25 mm.Ice cubes per cycle (15).Evaporator made of treaty cooper, dump ice cubes by reverse cycle "hot gas".No thermostat in the tank "too full", automatic interruption of the cycle, (the production stops when empty all the ice cubes stored in reserve).Inwardly sliding door, easy access ensuring strength and...
%
Production 31kg/24 h., capacity reserve 12kg. "Palettes" system, particularly suitable for the hardest water conditions or bad quality water (algae, mud).Hollow ice cubes 20 g, ø 30 mm, h 25 mm.Ice cubes per cycle (15).Evaporator made of treaty cooper, dump ice cubes by reverse cycle "hot gas".No thermostat in the tank "too full", automatic interruption of the cycle, (the production stops when empty all the ice cubes stored in reserve).Inwardly sliding door, easy access ensuring strength and...
%
Production 32 kg/24 h., capacity reserve 12kg. "Palettes" system, particularly suitable for the hardest water conditions or bad quality water (algae, mud).Hollow ice cubes 20 g, ø 30 mm, h 25 mm.Ice cubes per cycle (15).Evaporator made of treaty cooper, dump ice cubes by reverse cycle "hot gas".No thermostat in the tank "too full", automatic interruption of the cycle, (the production stops when empty all the ice cubes stored in reserve).Inwardly sliding door, easy access ensuring strength and...
%
Production 48 kg/24 h., capacity reserve 25 kg. "Paddle" system, particularly suitable for the hardest water conditions or bad quality water (algae, mud).Hollow ice cubes 20 g, ø 30 mm, h 25 mm.Ice cubes per cycle (15).Evaporator made of treaty cooper, dump ice cubes by reverse cycle "hot gas".No thermostat in the tank "too full", automatic interruption of the cycle, (the production stops when empty all the ice cubes stored in reserve).Inwardly sliding door, easy access ensuring strength and...
%
Production 55 kg/24 h., capacity reserve 30 kg. "Paddle" system, particularly suitable for the hardest water conditions or bad quality water (algae, mud).Hollow ice cubes 20 g, ø 30 mm, h 25 mm.Ice cubes per cycle (15).Evaporator made of treaty cooper, dump ice cubes by reverse cycle "hot gas".No thermostat in the tank "too full", automatic interruption of the cycle, (the production stops when empty all the ice cubes stored in reserve).Inwardly sliding door, easy access ensuring strength and...
%
Production 75 kg/24 h., capacity reserve 37kg. "Paddle" system, particularly suitable for the hardest water conditions or bad quality water (algae, mud).Hollow ice cubes 20 g, ø 30 mm, h 25 mm.Ice cubes per cycle (15).Evaporator made of treaty cooper, dump ice cubes by reverse cycle "hot gas".No thermostat in the tank "too full", automatic interruption of the cycle, (the production stops when empty all the ice cubes stored in reserve).Inwardly sliding door, easy access ensuring strength and...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...