%
Capacity 10 GN 2/1 levels (or 20x GN 1/1).Upper section fitted with stainless steel gallery on 4 sides.Construction in stainless steel AISI 304.Walls and door made of dual injected walls (polyurethane CFC-free high density).Possibility of use GN 2/1 or GN 1/1 spaced 70 mm.Homogeneity of the temperature through an internal ventilator.Cross bowl stamped with rounded corners.Hinged door with opening at 270°, equipped with a key lock with a seal in the door frame, easily replaceable without...
%
Capacity 20 GN 2/1 levels (or 40x GN 1/1).Construction in stainless steel AISI 304.Walls and door made of dual injected walls (polyurethane CFC-free high density).Possibility of use GN 2/1 or GN 1/1 spaced 70 mm.Homogeneity of the temperature through an internal ventilator.Cross bowl stamped with rounded corners.Hinged door with opening at 270°, equipped with a key lock with a seal in the door frame, easily replaceable without tools.Equipped with 4 wheels Ø 160 mm in stainless steel, 2 with...
%
Capacity 40 GN 2/1 levels (or 80x GN 1/1).SPECIAL BANQUETING: Standard 20 grids to optimize space inside the trollley. Up to eight (8) plates with a diameter of 300 mm can be stored per level, for a total of 160 plates.Construction in stainless steel AISI 304.Walls and door made of dual injected walls (polyurethane CFC-free high density).Possibility of use GN 2/1 or GN 1/1 spaced 70 mm.Homogeneity of the temperature through an internal ventilator.Cross bowl stamped with rounded corners.Hinged...
%
Chamber: 420x420x140 mm2 stackable ovens (1+1)Stainless steel front, painted steel frame.Chamber with refractory stone base, thick rock wool insulationSmall smoke evacuation chimneyHigh T°" interior lighting, recessed, avoiding any impactDoor with "athermal" handle, large safety glass windowHeating by stainless steel armoured resistorsT° control (450°C), safety thermostat as standardThe device is built in compliance with the current CE standards.
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...