Mechanical controls, mats manipulated by joystick.Table version (very compact), 4 adjustable cylinders.Manual controlsVariable speed (10 rpm to 60 rpm), with Inverter.Side tables 700x500 mm (foldable)Cylinder length 500 mmRoll opening 0 - 36 mm, rolling diameter 60 mmTravel speed 35 metres/minuteClosed overall dimensions 380x920xh850.Standard: 2 pastry rollers.Strips made with specific materials for food use.Precise regulation of the thickness of the dough sheet, constant production.Scrapers...
%
Mechanical controls, mats manipulated by joystick.Table version (very compact), 4 adjustable cylinders.Manual controls.1 speed.Side tables 700x500 mm (foldable).Cylinder length 500 mm.Roll opening from 0 - 36 mm, rolling diameter 60 mm.Travel speed 35 metres/minute.Closed overall dimensions 380x920xh850.Standard: 2 pastry rollers.Strips made with specific materials for food use.Precise regulation of the thickness of the dough sheet, constant production.Scrapers and supports made with specific...
%
Production 2400/800 pieces/h.Portions from 50 to 300 gr. "Millimetric" cut check by photocell.Transparant lid with micro-switch.Tank capacity 30 kg, knives and endless screws made of stainless steel.24-V low voltage control panel.Safety micro-switch.Entirely dismountable for an easy maintenance.Outside realization made of "epoxy paint" steel.Delivered with 2 forms CN/45 & CN70, base & pouring funnel for coupling BSL-300A.
%
Production 2400/800 pieces/h.Portions from 50 to 300 gr. "Millimetric" cut check by photocell.Transparant lid with micro-switch.Tank capacity 30 kg, knives and endless screws made of stainless steel.24-V low voltage control panel.Safety micro-switch.Entirely dismountable for an easy maintenance.Outside realization made of "epoxy paint" steel.Delivered with 2 forms CN/45 & CN70, base & pouring funnel for coupling BSL-300A.
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...