Included: 3 grids GN 2/1 (530x650 mm).4 adjustable stainless steel feet.Refrigerant gas R290.Interior and exterior made of stainless steel (food grade) AISI 304 (rear galvanized steel), monocoque frameStainless steel racks and slides (antitilt), allowing the grids to be positioned as desired, deep-drawn inner bottom and rounded corners and angles (without rough edges)Doors with ergonomic (not protruding) and reversible handle, closing by "triple chamber" and magnetic seal (easy replacement,...
%
Included: 3 grids GN 2/1 (530x650 mm) by door.Inner door with warm resistance.Depression valve delivered standard.4 adjustable stainless steel feet.Refrigerant gas R290.Interior and exterior made of stainless steel (food grade) AISI 304 (rear galvanized steel), monocoque frameStainless steel racks and slides (antitilt), allowing the grids to be positioned as desired, deep-drawn inner bottom and rounded corners and angles (without rough edges)Doors with ergonomic (not protruding) and...
%
%
%
%
%
%
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Included: 20 pairs of slides (400x600 mm).Inner door with warming element and depression valve.4 adjustable stainless steel feet.Cooling gas R290.Manufactured in stainless steel AISI 304, inside and outside (back in galvanized steel), monocoque frame.Stainless steel racks and slides (anti-tilting), allowing to place the plates as one pleases, stamped interior bottom, rounded angles and corners (without roughness).Doors with ergonomic handle (no salient) and reversible, closed by magnetic seal...
%
Included: 20 pairs of slides (600x800 mm).Inner door with warming element and depression valve.4 adjustable stainless steel feet.Cooling gas R290.Manufactured in stainless steel AISI 304, inside and outside (back in galvanized steel), monocoque frame.Stainless steel racks and slides (anti-tilting), allowing to place the plates as one pleases, stamped interior bottom, rounded angles and corners (without roughness).Doors with ergonomic handle (no salient) and reversible, closed by magnetic seal...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
%
Glass loading height 300 mm.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150".3 phases: washing, unloading, rinsing.Drain pump as standardRinsing pump as standard (atmospheric boiler).Made of stainless steel AISI 304. Rotating washing and rinsing arms (upper and lower). Self-cleaning nozzles. Tank with rounded edges (8 lt - 0,6 kW). Stamped basket slides, no roughness and no limestone incrustation. Integral filter in "Composit" tank. Patented" pump filter to keep the washing water longer...