%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work
%
- Air condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
- Water condenser.- Vertical turbine with automatic extraction.- Minimum mixing capacity 3 lit. and maximum 7 lit.- Noise level below 70 dB.- Vertical evaporator cylinders for a larger exchange surface.- Cycle with time control or temperature control.- Exclusive distribution device. - System self diagnosis.- Cycle time: 8/12 min.- Hourly production: 50 litres.NB: mainly for cold work.
%
%
%
%
For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
Vacuum pump capacity 8m3/h. (Busch type)Cycle time 15-30 seconds.Chamber dimensions: 350x370xh150mm (Seal length: 350mm).Delivered with volume insertion plate, for a fast cycle and a good positioning of your products_backup_1_1.Digital control panel, 1 memorizable program, maintenance and cleaning program of the pump.On request: inclined plate for liquid products_backup_1_1, ....Professional table-top machinesVacuum is managed in % thanks to the integrated vacuum sensor, eliminating the risk...
%
Vacuum pump capacity 16m3/h. (Busch type)Cycle time 20-40 seconds.Chamber dimensions: 420x370xh135 mm (Seal length: 420mm).Delivered with volume insertion plate, for a fast cycle and a good positioning of your products_backup_1_1.Digital control panel, 1 memorizable program, maintenance and cleaning program of the pump.On request: inclined plate for liquid products_backup_1_1, 2 seal bars, ...Professional table-top machinesVacuum is managed in % thanks to the integrated vacuum sensor,...
%
Vacuum pump capacity 4m3/h. (Busch type)Cycle time 25-60 seconds.Chamber dimensions: 280x310xh85 mm (Seal length: 280mm).Delivered with volume insertion plate, for a fast cycle and a good positioning of your products_backup_1_1.Digital control panel, 1 memorizable program, maintenance and cleaning program of the pump.On request: inclined plate for liquid products_backup_1_1 and transparent curved cover. Professional table-top machinesVacuum is managed in % thanks to the integrated vacuum...
%
%
Control panel with LCD display (IVP: INTELLIGENT VACUUM PACKAGING), maintenance program and pump cleaning.Vacuum pump capacity 16m3/h. (Busch type)Cycle time 15-30 seconds.Chamber dimensions: 350x370xh150 mm (Seal length: 350mm)Delivered with a volume insert plate, for a fast cycle and a good positioning of your products_backup_1_1.Soft air: gradual vacuuming.On request: Liquid control sensor, inclined plate for liquid products_backup_1_1, gas injection system "nitrogen", ...Vacuum machine...
%
Vacuum pump capacity 16m3/h.(Busch type)Cycle time 15-30 seconds.Chamber dimensions: 350x370xh150 mm (Seal length: 350mm).Delivered with volume insertion plate, for a fast cycle and a good positioning of your products_backup_1_1.Digital control panel with 10 programs, maintenance program and pump cleaning.Soft air: gradual vacuuming. On request: Liquid control sensor, inclined plate for liquid products_backup_1_1, gas injection system "nitrogen", ... Professional table-top machines for vacuum...