Included: 20 pairs of runners (400 x 600 mm).Inner door with heating resistance and under-pressure valve.4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without...
%
Included: 20 pairs of runners (600 x 800 mm).Inner door with heating resistance and under-pressure valve.4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without...
%
Included: 20 pairs of runners (400 x 600 mm).4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without bumps).Doors with ergonomic (not projecting) and reversible...
%
Included: 20 pairs of runners (600 x 800 mm).4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without bumps).Doors with ergonomic (not projecting) and reversible...
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Production 105 kg per 24/h, reserve in ABS.Air condenser. Vertical evaporator "Concept FAST FOOD". Ice cubes 7 g. Tropicalized hermetic unit, ambient temperature +43°CRefrigerant gas R404a or R452a.Made of stainless steel AISI 304, adjustable feet.The unit is built in compliance with current CE standards.
%
Production 105 kg per 24/h, reserve in ABS.Water condenser. Vertical evaporator "Concept FAST FOOD".Ice cubes 7 g.Tropicalized hermetic unit, ambient temperature +43°CRefrigerant gas R404a or R452a.Made of stainless steel AISI 304, adjustable feet.The unit is built in compliance with current CE standards.
%
Production unit combined with a storage unit.Production 200 kg per 24/h.Air condenser. System with vertical evaporator (concept for fast food).Flat ice cubes of 7gTropicalized hermetic unit with ambient temperature +43°CRefrigerant gas R404a or R452aMade of stainless steel AISI 304.The unit is built in compliance with the current (CE) standards.
%
Production unit combined with a storage unit.Production 225 kg per 24/h.Water condenser. System with vertical evaporator (concept for fast food).Flat ice cubes of 7gTropicalized hermetic unit with ambient temperature +43°CRefrigerant gas R404a or R452aMade of stainless steel AISI 304.The unit is built in compliance with the CE standards in force.
%
Production unit combined with a storage unit.Production 400 kg per 24/h.Air condenser. System with vertical evaporator (concept for fast food).Flat ice cubes of 7gTropicalized hermetic unit with ambient temperature +43°CRefrigerant gas R404a or R452aMade of stainless steel AISI 304.The unit is built in compliance with the current (CE) standards.
%
Production unit combined with a storage unit.Production 415 kg per 24/h.Air condenser. System with vertical evaporator (concept for fast food).Flat ice cubes of 7gTropicalized hermetic unit with ambient temperature +43°CRefrigerant gas R404a or R452aMade of stainless steel AISI 304.The unit is built in compliance with the CE standards in force.