For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
Standard equipment: a double perforated bottom where to place the sushis. Stainless steel construction (Austenitic - Food) and anodized aluminum finishing.Sliding back doors in glass, front window in "toughened glass", curved.Drain for the condensate.Regulation by electronic thermostat (digital).Lighting by "LED".Built-in group (Energy Class 4), quiet, ventilated condenser.Copper evaporator "serpentine" below the tank, also an upper fin evaporator (hidden), refrigerant gas R600a.Adjustable...
%
Système de refroidissement par groupe monobloc, classe climatique 4 (température 30°C et humidité 55%). Évaporateur ventilé.Gaz réfrigérant R455a.Régulation électronique, température +2°C +8°C.Dégivrage automatique.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
Standard equipment: 6 trays GN 1/3 high 40 mm. Stainless steel construction (Austenitic - Food) and anodized aluminum finishing.Sliding back doors in glass, front window in "toughened glass", curved.Copper evaporator "serpentine" below the tank, refrigerant R600a, drain for the condensate.Regulation by electronic thermostat (digital), Lighting by "LED". NB Provide discharge (or) a condensate drain pan.
%
Essential equipment to guarantee a 100% hygiene..Storage Cabinet made of stainless steel, interior and exterior, stainless steel floor.Removable panels, with assembly hooks.Insulation of 40 mm, in polyurethane without CFC.Can recieve 240 liters dustbins (not included)Upper valves for emptying the waste.
%
%
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
Standard equipment: a double perforated bottom where to place the sushis. Stainless steel construction (Austenitic - Food) and anodized aluminum finishing.Sliding back doors in glass, front window in "toughened glass", curved.Drain for the condensate.Regulation by electronic thermostat (digital).Lighting by "LED".Built-in group (Energy Class 4), quiet, ventilated condenser.Copper evaporator "serpentine" below the tank, also an upper fin evaporator (hidden), refrigerant gas R600a.Adjustable...
%
Essential equipment to guarantee a 100% hygiene..Storage Cabinet made of stainless steel, interior and exterior, stainless steel floor.Removable panels, with assembly hooks.Insulation of 40 mm, in polyurethane without CFC.Can recieve 240 liters dustbins (not included)Upper valves for emptying the waste.
%
%
%
Standard equipment: 8 trays GN 1/3 high 40 mm. Stainless steel construction (Austenitic - Food) and anodized aluminum finishing.Sliding back doors in glass, front window in "toughened glass", curved.Copper evaporator "serpentine" below the tank, refrigerant R134A, drain for the condensate.Regulation by electronic thermostat (digital).Lighting by "LED".Built-in group (Energy Class 4), quiet, ventilated condenser.Adjustable feet.NB Provide discharge (or) a condensate drain pan.
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.