For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
Electronic regulation T° 20° to 95°, high precision (0,03 C°), 25 preset programs (that can be modified as one pleases) or manual mode.Water agitator with propeller, uniform T°.Delayed start option for each programme from 10 minutes to 24 hours (in 10 minute steps).Quick changeover of the display between selected T°, actual T°, preset time, remaining time as well as the display from C° to F°.Clamp for any container (max H.165 mm, 50 l max).Stainless steel handle.Safety device and agitator...
%
2 independent heating sources selected by switch and regulated by thermostat (+20° +90°C) with indicator light.Ceramic resistance above the tray.Reinforced lower resistance under the tank.Pressed fully tilted for emptying without oil residue, curved pan totally removable drip.Drain by stainless steel tap with safety system.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
%
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
General characteristics:Tank GN 1/1-h 200 mm. Tank capacity 27 L.Athermique handles (for easy transportation).Transparent cover in polycarbonate, series (less energetic consume).Made in stainless steel AISI 304.
%
%
General characteristics:Tank GN 2/1-h 200 mm.Tank capacity 50 Lit .Athermique handles (for easy transportation).Cover, transparent in polycarbonate (less energetic consume).Made in stainless steel AISI 304.
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.