For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
Realisation "double walled". with thermic insulation.Watersoftener continuously, incorporated (WARNING: connection to cold water).Charging height diam. 465 mm.Standard rinsing pump (atmospheric boiler). Control panel at the top of the hood, digital display.Basket 600x500 mm, capacity 22 plates, dishes 600x400 (see accessories), beer baskets 600x400 to 135 Lt, always the possibility of using 500x500 mm baskets. 3 cycles: 60 '- 110' - 150 '' or continuous.Device opening and closing cover on...
%
- Capacity : 4 ice tray of 6,5 lit., 5 lit., 3 lit. or 8 ice tray of 2,5 lit.- Structure made of ABS white, plexiglas lid.- Copper evaporator.- Gas cooling R404a.- Insulation without "CFC".- Maintenance and maintains easy.NB: delivered without ice trays.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
- Capacity : 4 ice tray of 6,5 lit., 5 lit., 3 lit. or 8 ice tray of 2,5 lit.- Structure made of ABS, plexiglas lid.- Copper evaporator.- Gas cooling R290.- Insulation without "CFC".- Maintenance and maintains easy.NB: delivered without ice trays.
%
Realization in "double walls" with thermal insulationIntegration of the "Green System H.R.S. Condenser-recovery of vapors, great energy saving (ATTENTION: connection to cold water)Continuous water softener, incorporated (ATTENTION: connection to cold water)Loading height 465 mmStandard flush pump (atmospheric boiler). Control panel on top of the cover, digital displayBasket 600x500 mm, capacity 22 plates, plates 600x400 (see accessory), beer baskets 600x400 up to 135 Lt, still possible to use...
%
%
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
%
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
Water softener continuously, incorporated (ATTENTION: cold water connection) Height of load Ø 465 mm.Realisation "double walled". with thermic insulation.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150" or continuous.3 phases: wash, unload, rinse.Water consumption per cycle 3 liters.Vertical wash pump (double flux), auto-drain and auto-wash (1,5 Kw).Standard discharge pump.Standard rinse pump (atmospheric boiler) Control panel at the top of the hood, digital display.Basket 600x500 mm,...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
Integration of the "Green System H.R.S." Condenser vapor-recovery unit, big energy savings (ATTENTION: connection to cold water)Watersofterner continuously, incorporated. (ATTENTION: connection to cold water)Height of load Ø 465 mmRealisation "double walled". with thermic insulation.From 60 to 24 baskets/hour, PLD cycles 60", 120", 150" or continuous.3 phases: wash, unload, rinse.Water consumption per cycle 3 liters.Standard discharge pump.Standard rinse pump (atmospheric boiler) Control...
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.