For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
Realisation in anodized aluminium.Cylinder diameter 100 mm.
%
Realisation "double walled".Loading height for trays 380 mm (plates diam. 380 mm).LMD mixed washing, also dishes, cutleryStandard rinsing pump (atmospheric boiler)Made of double walls made of stainless steel AISI 304.Cycles 60'' - 120"-80" or continuous.Rotating washing and rinsing arms (upper and lower) (stainless steel lower).Self cleaning sprinklers.Tank (23Lit. 2,1Kw) with rounded edges, "deep-drawn" bottom."Integral" tank filter, made of "cast" stainless steel.Adjustable stainless steel...
%
GN 1/1 inner tank, made in stainless steel, removable tank.Heating by gas, stainless steel burners placed under the tank.Tap gas control, lighter, stainless steel structure.Adjustable feet.Stainless steel frame.NB delievered without GN containers!
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
Realisation in anodized aluminium.Cylinder diameter 130 mm.
%
Realisation "double walled".Loading height for trays 650mmCID door (double wall) with automatic closing "soft contact" (partial opening for steam evacuation)Double door guillotine (isolated double wall) and counterbalanced.Standard rinsing pump (atmospheric boiler)Cycles 120''- 240'' - 360'' or continuous.Rotating washing and rinsing arms.Self-cleaning nozzles.Deep-drawn walls.Adjustable stainless steel feet (160-220 mm).Removable control panel.USB" port for software update.Pump increasing...
%
With frontal drainage tap.Designed in stainless steel.Stainless steel tank AISI 304, stamped GN 1/1 (for tray height 150 mm).Stainless steel shielded element heating, placed below the tank.On/Off switch, thermostat from 0° to 90°C and safety thermostat.Appliances are complied with the CE in force.NB: Delivered without GN trays.
%
%
Realisation "double walled".Loading height for trays 850mmCID door (double wall) with automatic closing "soft contact" (partial opening for evacuation of the steam)Double door guillotine (isolated double wall) and counterbalanced.Standard rinsing pump (atmospheric boiler)Cycles 120''- 240'' - 360'' or continuous.Rotating washing and rinsing arms.Self-cleaning nozzles.Deep-drawn walls.Adjustable stainless steel feet (160-220 mm).Removable control panel.USB" port for software update.Pump...
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
Realisation "double walled".Loading height for trays 850mmCID door (double wall) with automatic closing "soft contact" (partial opening for evacuation of the steam)Double door guillotine (isolated double wall) and counterbalanced.Standard rinsing pump (atmospheric boiler)Cycles 120''- 240'' - 360'' or continuous.Rotating washing and rinsing arms.Self-cleaning nozzles.Deep-drawn walls.Adjustable stainless steel feet (160-220 mm).Removable control panel.USB" port for software update.Pump...
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.