%
For motor type:7/7/14 - 9/9/9 - 9/9/14 - 10/10/9 - 10/10/14.On/Off switch and potentiometer speed variatorOn/Off lighting switch.
%
For motor type:12/9/9 - 12/12/9.On/Off switch and potentiometer speed variator.On/Off lighting switch.
%
%
Voor ventilator motor van het type:9/9/14 - 12/9/9.- On / off schakelaar en snelheid variator door potontiometer.
%
%
Voor ventilator motor van het type:7/7/14 - 9/9/9 - 10/10/9 - 10/10/14.- On / off schakelaar en snelheid variator door potontiometer.
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for indoor use, IP20 protection ratingExternal control terminal. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5 seconds).Intensive operation up to an ambient temperature of -20° to +50°C (storage temperature: -40° to +60°C).Quick commissioning.Basic...
%
For motor: CVX/4T - CVX/6T - CVX/8TSuitable for outdoor use, IP66 protection rating // NEMA 4X resistant to ultraviolet (UV) rays, grease, oil, and acids.Potentiometer for speed control.Forward/reverse selector.Power disconnect switch. Control panel with digital screen.Three-phase input / three-phase output (3x400V / 3x400V).EMC filter (electromagnetic compatibility).Input frequency: 48-62 Hz, output frequency: 0-500 Hz.Accepts an overload of 150% for 60 seconds (175% for 2.5...
%
For motor type variator : CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type: CA10/8/30 - CA12/12/45 - CVX/8M.Protection class: IP50Maximum motor power absorption: 8AMaximum light power absorption: 5A Variator for motor, light, and solenoid valve control.On/off switch and speed variator with potentiometer.On/off switch for lighting.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor type variator: CA7/7/15 - CA9/7/25 - CVX/2M - CVX/4M - CVX/6M.Protection class: IP55Maximum motor power absorption: 4.5A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
For motor: CA10/8/30 - CA12/12/45 - CVX/8MProtection class: IP50Maximum motor power absorption: 8A Variator for motor and solenoid valve control.On/off switch and speed variator with potentiometer.Management of gas solenoid valve (230V/1N-50Hz, max. 1A)Protection fuse and speed calibration potentiometers MIN & MAX.
%
Temperature setting on each tank (+2° to +8°C).Polycarbonate tanks, ABS cover, equipped with metering valve, completely removable for easy maintenance.Rotating pallet system (thus avoiding foam problems).Tropicalized thermal unit (ambient temperature +43°C).Refrigerant evaporator in stainless steel AISI 304.Refrigerant gas R290The device is built in compliance with the current CE standards.
%
Temperature setting on each tank (+2° to +8°C).Polycarbonate tanks, ABS cover, equipped with metering valve, completely removable for easy maintenance.Rotating pallet system (thus avoiding foam problems).Tropicalized thermal unit (ambient temperature +43°C).Refrigerant evaporator in stainless steel AISI 304.Refrigerant gas R290The device is built in compliance with the current CE standards.
%
4 plates, 2x 2,6 kW Ø220mm and 2x 1,5 kW Ø145mm, 6 position regulation. Cast iron plates, regulation by 6 positions switch.Neutral GN 2/1 cabinet (optional doors).NB: heating kit, optional.
%
4 burners 4x 5,5 Kw High Efficiency-Flexibility.Neutral GN 2/1 cabinet (doors optional). Deep-drawn top, cast iron burners, brass crown (high efficiency).Regulation by gas valve, ignition by pilot light and safety by thermocouple.NB: smooth or ribbed plates, heating kit, optional.
%
6 burners 6x 5,5 Kw High Efficiency-Flexibility.Neutral GN 2/1 cabinet (doors optional). Deep-drawn top, cast iron burners, brass crown (high efficiency).Regulation by gas valve, ignition by pilot light and safety by thermocouple.NB: smooth or ribbed plates, heating kit, optional.
%
Temperature regulator for drink from +2°C to +8°C.System rotating spatulas (preventing the formation of foam).Polycarbonate trays.Fully removable for daily maintenance.Refrigerating evaporator in AISI 304 stainless steel.AISI 304 stainless steel structure.Tropicalized thermal unit (ambient temperature +43°C).Refrigerant gas R290The appliance is built in compliance with current (CE) standards.
%
Temperature regulator for drink from +2°C to +8°C.System rotating spatulas (preventing the formation of foam).Polycarbonate trays.Fully removable for daily maintenance.Refrigerating evaporator in AISI 304 stainless steel.AISI 304 stainless steel structure.Tropicalized thermal unit (ambient temperature +43°C).Refrigerant gas R290The appliance is built in compliance with current (CE) standards.
%
4 burners, 2x 3.6 kW and 2x 5 kW.Burner: worked cast-iron, crown of burner: in brass (with very high ourput), thermocouple protection.Made stainless steel. Adjustable feet in stainless steel.
%
6 burners, 3x 3,6 kW and 3x 5 kW.Worked cast-iron burner, brass crown burner (with very high output), thermocouple protection.Made stainless steel. Adjustable feet in stainless steel.
%
3 breadroll heathers. Pirex glasscontainer +/- 40 sausages resting upon a water tub. Cover in stainless steel.Energy regulator.2 athermic handles.
%
2 breadroll heathers. Pirex glasscontainer +/- 40 sausages resting upon a water tub. Cover in stainless steel.Energy regulator.2 athermic handles.