Stainless steel tube structure AISI 304 18/10 Ø 25 mm.Top and shelf 1000x500 mm in stainless steel AISI 304 submerged and soundproof.Useful loading capacity 80 kg per shelf.4 swivel castors with stubborn Ø 125 mm, 2 with brake.Can be dismantled.
%
Stainless steel tube structure AISI 304 18/10 Ø 25 mm.Top and shelf 800x500 mm in stainless steel AISI 304 submerged and soundproof.Useful loading capacity 80 kg per shelf.4 swivel castors with stubborn Ø 125 mm, 2 with brake.Can be dismantled.
%
Stainless steel tube structure AISI 304 18/10 Ø 25 mm.Top and shelf 1000x500 mm in stainless steel AISI 304 submerged and soundproof.Useful loading capacity 80 kg per shelf.4 swivel castors with stubborn Ø 125 mm, 2 with brake.Can be dismantled.
%
- Stainless steel tube structure AISI 304 18/10 Ø 25 mm.- Top and shelf 1000x500 mm in stainless steel AISI 304 submerged and soundproof.- 4 swivel castors with stubborn Ø 125, 2 with brake.
%
Stainless steel tube structure AISI 304 18/10 Ø 25 mm.Top and shelf 1000x500 mm in stainless steel AISI 304 submerged and soundproof.Useful loading capacity 150 kg per shelf.4 swivel castors with stubborn Ø 125, 2 with brake.Strengthened structure.
%
Stainless steel tube structure AISI 304 18/10 Ø 25 mm.Top and shelf 1000x500 mm in stainless steel AISI 304 submerged and soundproof.Useful loading capacity 150 kg per shelf.4 swivel castors with stubborn Ø 125, 2 with brake.Strengthened structur.
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...