Fonctions :Possibility of inserting food having a temperature until 90° C.- Version NNC: 3 cycles personnalisables (software +3°C, hardware +3°C,maintenance), version BCC: 5 cycles personnalisables (software +3 or -18°C, hardware +3 or -18°C, maintenance), specific cycles for the ice cream.- Function CRUISE.- Function CCRT which considers the residual time remaining before the end of the cycle.- Function TURBO CCTC especially conceived for the continuously production.- Sensor with 3 probes...
%
Fonctions :Possibility of inserting food having a temperature until 90° C.- Version NNC: 3 cycles personnalisables (software +3°C, hardware +3°C,maintenance), version BCC: 5 cycles personnalisables (software +3 or -18°C, hardware +3 or -18°C, maintenance), specific cycles for the ice cream.- Function CRUISE.- Function CCRT which considers the residual time remaining before the end of the cycle.- Function TURBO CCTC especially conceived for the continuously production.- Sensor with 3 probes...
%
LENGTHWISE" cell for loading GN 1/3, 1/2, 2/3 and 1/1 plates.Load capacity: 6x GN1/1 or 5x 600x400mm.Production per cycle: 30Kg (+70° +3°) and 30Kg (+70° -18°).Chamber size: 505x705xh450mm.Core probe.Built-in compressor unit.NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm thick, stainless steel feet.Speaker: rounded corners and angles without roughness....
%
LENGTHWISE" cell for loading GN 1/3, 1/2, 2/3 and 1/1 plates.Load capacity: 10x GN1/1 or 8x 600x400mm.Production per cycle: 50Kg (+70° +3°) and 50Kg (+70° -18°).Chamber size: 505x705xh900mm.Core probe.Built-in compressor unit.NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm thick, stainless steel feet.Speaker: rounded corners and angles without roughness....
%
Cell for loading GN 2/1 (or GN 1/1).Load capacity: 10x GN2/1 or 8x 600x400mm.Production per cycle: 100Kg (+70° +3°) and 70Kg (+70° -18°).Chamber size: 670x843xh900mm.Core probe.Built-in compressor unit.NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm thick, stainless steel feet.Speaker: rounded corners and angles without roughness. Deep-drawn bottom that...
%
LENGTHWISE" cell for loading GN 1/3, 1/2, 2/3 and 1/1 plates.Load capacity: 20x GN1/1 or 16x 600x400mm.Production per cycle: 100Kg (+70° +3°) and 85Kg (+70° -18°).Chamber size: 525x705xh1453mm.Core probe.Compressor unit not included.Trolley & charger 600x400 EURONORM (on request ref: AC/2P2...)NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm thick,...
%
Cell for loading plates GN 2/1 (or GN 1/1).Load capacity: 20x GN2/1 or 16x 600x400mm.Production per cycle: 200Kg (+70° +3°) and 170Kg (+70° -18°).Chamber size: 780x946xh1850mm.Cell delivered disassembled.Core probe.Compressor unit not included.Trolley & charger 600x400 EURONORM (on request ref: AC/2P2...)NB: delivered without grids and GN plates. Interior and exterior construction in AISI 304 stainless steel, monobloc structure, expanded polyurethane insulation, CFC and HCFC-free, 60 mm...
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...