%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Timer from 0 to 60 minutes (can be programmed 24 hours in advance).Construction in stainless steel AISI 304.IMPORTANT: Please follow the instructions for use carefully! 2 fans.Nominal production capacity: 112g/h.Can be adjusted via a mobile application (via NFC connection).For a concentration of 1ppm (parts per million), suitable for rooms up to 480m² / 1440m³ (in 20 minutes), 960 m² / 2880 m³ (in 40 minutes), 1440m² / 4320 m³ (in 60 minutes).For a concentration of 2ppm (parts per million),...
%
Timer from 0 to 60 minutes (can be programmed 24 hours in advance).Construction in stainless steel AISI 304.IMPORTANT: Please follow the instructions for use carefully! 2 fans.Nominal production capacity: 112g/h.Can be adjusted via a mobile application (via NFC connection).For a concentration of 1ppm (parts per million), suitable for rooms up to 480m² / 1440m³ (in 20 minutes), 960 m² / 2880 m³ (in 40 minutes), 1440m² / 4320 m³ (in 60 minutes).For a concentration of 2ppm (parts per million),...
%
Timer from 0 to 60 minutes.AISI 304 stainless steel construction.IMPORTANT: Please follow the instructions for use carefully! 1 fan.Rated output: 56g/h.At a concentration of 1ppm (parts per million), suitable for rooms up to 240m² / 720m³ (in 20 minutes), 480 m² / 1440 m³ (in 40 minutes), 720m² / 2160 m³ (in 60 minutes).For a concentration of 2ppm (parts per million), suitable for rooms up to 120m² / 360m³ (in 20 minutes), 240 m² / 720 m³ (in 40 minutes), 360m² / 1080 m³ (in 60 minutes).
%
Flow rate: 3000 m³/o. (Pressure drop 380 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 4500 m³/o. (Pressure drop 220 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 1300 m³/o. (Pressure drop 200 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 2500 m³/o. (Pressure drop 210 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 2200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 3200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 315 mm.Airflow: 4200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 350 mm.Airflow: 5600 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
%