Included: 20 pairs of runners (400 x 600 mm).Inner door with heating resistance and under-pressure valve.4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without...
%
Included: 20 pairs of runners (600 x 800 mm).Inner door with heating resistance and under-pressure valve.4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without...
%
Included: 20 pairs of runners (400 x 600 mm).4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without bumps).Doors with ergonomic (not projecting) and reversible...
%
Included: 20 pairs of runners (600 x 800 mm).4 adjustable stainless steel feet.Cooling gas R134.Interior and exterior made of (food) stainless steel AISI 304 (back made of galvanized steel), monocoque frame.Racks and rails in stainless steel (maximal capacity 27 slides, 50-mm spacing), which help to position the trays as one pleases, stamped inside bottom, with drain plug (major maintenance) and rounded angles and corners (without bumps).Doors with ergonomic (not projecting) and reversible...
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Flow rate: 3000 m³/o. (Pressure drop 380 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 4500 m³/o. (Pressure drop 220 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 1300 m³/o. (Pressure drop 200 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 2500 m³/o. (Pressure drop 210 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 2200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 3200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 315 mm.Airflow: 4200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 350 mm.Airflow: 5600 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
%
%