Production 105 kg per 24/h, reserve in ABS.Air condenser. Vertical evaporator "Concept FAST FOOD". Ice cubes 7 g. Tropicalized hermetic unit, ambient temperature +43°CRefrigerant gas R404a or R452a.Made of stainless steel AISI 304, adjustable feet.The unit is built in compliance with current CE standards.
%
Production 105 kg per 24/h, reserve in ABS.Water condenser. Vertical evaporator "Concept FAST FOOD".Ice cubes 7 g.Tropicalized hermetic unit, ambient temperature +43°CRefrigerant gas R404a or R452a.Made of stainless steel AISI 304, adjustable feet.The unit is built in compliance with current CE standards.
%
Production unit combined with a storage unit.Production 200 kg per 24/h.Air condenser. System with vertical evaporator (concept for fast food).Flat ice cubes of 7gTropicalized hermetic unit with ambient temperature +43°CRefrigerant gas R404a or R452aMade of stainless steel AISI 304.The unit is built in compliance with the current (CE) standards.
%
Production unit combined with a storage unit.Production 225 kg per 24/h.Water condenser. System with vertical evaporator (concept for fast food).Flat ice cubes of 7gTropicalized hermetic unit with ambient temperature +43°CRefrigerant gas R404a or R452aMade of stainless steel AISI 304.The unit is built in compliance with the CE standards in force.
%
Production unit combined with a storage unit.Production 400 kg per 24/h.Air condenser. System with vertical evaporator (concept for fast food).Flat ice cubes of 7gTropicalized hermetic unit with ambient temperature +43°CRefrigerant gas R404a or R452aMade of stainless steel AISI 304.The unit is built in compliance with the current (CE) standards.
%
Production unit combined with a storage unit.Production 415 kg per 24/h.Air condenser. System with vertical evaporator (concept for fast food).Flat ice cubes of 7gTropicalized hermetic unit with ambient temperature +43°CRefrigerant gas R404a or R452aMade of stainless steel AISI 304.The unit is built in compliance with the CE standards in force.
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...