Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Frame in galvanized steel.Soundproof isolation.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Profile frame in aluminium.Panels with isolated double wall.Lateral inspection.Ventilator with direct suction.3 double filtering.
%
Top in stainless steel of 1.5 mm thickness.Multiple spring system.Heating through resistance, adjustable thermostat going form 30°C to 120°C.Submerged control panel, spiral cable 1.5 m.4 swivel castors Ø 125 mm, 2 with brake.Handle and 4 angle shock absorbers, non marking.Manufactured in stainless steel AISI 304, double wall isolation.
%
Flow rate: 3000 m³/o. (Pressure drop 380 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 4500 m³/o. (Pressure drop 220 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 1300 m³/o. (Pressure drop 200 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Flow rate: 2500 m³/o. (Pressure drop 210 Pa). Centrifugal double-inlet ventilation units with built-in motor (operating temperature/resistance: -20° to 40°).Enclosed motor, IP54 protection rating.Galvanized steel casing with 5 mm internal sound insulation (polyurethane foam).Side inspection for after-sales service (S.A.V.).
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 2200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 250 mm.Airflow: 3200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 315 mm.Airflow: 4200 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
Single-Phase Version.Pre-cut air inlet with a diameter of 350 mm.Airflow: 5600 m³/h (pressure drop: 200 Pa). Centrifugal single-inlet ventilation units with built-in motor (operating temperature/resistance: -20° +110°).Aluminum profiles and cladding panels made of galvanized "sandwich" type sheets with 20mm acoustic insulation (polyurethane foam).Panel with handle for easy access to the impeller for maintenance.Open motor access area for after-sales service inspection.Closed motor, IP54...
%
%
In-line wok burner Ø 290 mm (21.44 kW).Deep-drawn and waterproof cooking surface used to channel water for the cooling of the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 1/2").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
In-line wok type burners Ø 290 mm (21.44 kW).Deep-drawn and waterproof cooking surface used to channel water for cooling the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 3/4").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Burners type wok 2x Ø 290 mm 21,44 kW and 1x Ø 230 mm 10,13 kW.Embedded cooking top, catching basin underneath.Lateral drain, pouring basin with removable filter, foreseen of a cover and a drain hole.1 control vane per burner, gas connection (3/4").Water curtain for the cooling of the top, inclusive a tap and a ranging rack.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
In-line wok type burners Ø 290 mm 21,44 kW.Deep-drawn and waterproof cooking surface used to channel water for cooling the top.Lateral water drainage, equipped with an overflow drain.1 control valve per burner, connection (gas 3/4").Recuperation drawers.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).
%
Burners type wok 3x Ø 290 mm 21,44 kW and 2x Ø 230 mm 10,13 kW.Embedded cooking top, catching basin underneath.Lateral drain, pouring basin with removable filter, foreseen of a cover and a drain hole.1 control vane per burner, gas connection (4/4").Water curtain for the cooling of the top, inclusive a tap and a ranging rack.Made of AISI 441 stainless steel, Top of AISI 304 stainless steel (20/10th).