Version with incorporated water softener.Charging height 280 mm for dishes and 280mm for glasses. 30 baskets/hour, 120-second cycle.Rotating wash and rinse arms (upper and lower).Self-cleaning sprinklers.Tank (14 Lit., 2,1 kW) with rounded edges.Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety...
%
Charging height 280 mm for dishes and 280mm for glasses. 30 baskets/hour, 120-second cycle.Rotating wash and rinse arms (upper and lower).Self-cleaning sprinklers.Tank (14 Lit., 2,1 kW) with rounded edges.Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety thermostat.Manufactured in stainless...
%
Version with incorporated drain pump.Charging height 280 mm for dishes and 280mm for glasses. 30 baskets/hour, 120-second cycle.Rotating wash and rinse arms (upper and lower).Self-cleaning sprinklers.Tank (14 Lit., 2,1 kW) with rounded edges.Stamped walls.Double walled door.Removable control panel.Automatic filling of the tank.Check valve.Hot water rinse (water consumption per cycle 2 liters), boiler (pressure) in stainless steel (2,6 Lit., 2,6 kW).Micro switch, when the door opens.Safety...
%
Cast-iron plate, necessary measurements 365x255 mm.Stabilizing system in the upper plate, in order to keep the upper plate always in a horizontal position.Thermostat regulation up to 250°.
%
Plate in cast iron with ally for food, useful dimensions 225x255 mm.Stabilizing system in the top plate, allowing a constant horizontal position.Top plate handle in heatproof material.Heating resistances, situated under the cast iron plate.Regulation through thermostat till 250°C, together with a warning light.Structure in AISI 304 stainless steel.Adjustable lower legs.The equipment is manufactured following the (CE) standards in force
%
Plate in cast iron, useful dimensions 550x255 mm.Stabilizing system in the top plate, allowing a constant horizontal position.Regulation through thermostat till 250°C.
%
Upper plate gridlled, underplate flat all in vitroceramic.Easy maintenance working surface : 558 x 250 mm.Reception tub for liquids in front.Fitted with balanced springs on upper partRegulation thermostat till 250°C (from 20 till 200° in 4 min. till 300°C in 6 min). Low energy consumption.Chassis in stainless AISI 304.
%
Upper plate gridlled, underplate flat all in vitroceramic.Easy maintenance working surface : 370x250 mm.Reception tub for liquids in front.Fitted with balanced springs on upper partRegulation thermostat till 300°C (from 20 till 200° in 4 min. till 300°C in 6 min). Low energy consumption.Frame in stainless AISI 304.
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...