Designed in chromium-nickel-steel.Lid opening through pedal.Gradual closer of the lid by a hydraulic cylinder (soft contact).Front opening, stainless steel carrier bag.Full respect of HACCP norm (100% hygienic).Respect of fire-safety norms.2 feet and 2 castors behind facilitating every transfer.
%
Designed in stainless steel.Lid opening through pedal.Gradual closer of the lid by a hydraulic cylinder (soft contact).Front opening, stainless steel carrier bag.Full respect of HACCP norm (100% hygienic).Respect of fire-safety norms.2 feet and 2 castors behind facilitating every transfer.
%
Blade length 2020 mm.Height cap. 330 mm.AISI 304 stainless steel waterproof construction.Equipped with meat pusher and portion device.Interlocked waste tray is removable from outside.Removable door and upper pulley for easier cleaning.Aluminum pulleys with sealed ball bearings.Single-phase motors comes with standard thermal protection.Easy unlocking of the upper pulley allows for easier cleaning and blade replacement.Removable PVC scrapers.IP 54 24 V on/off switch with safety microswitch.The...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
%