Vacuum pump capacity 63m3/h (Busch type).Cycle time 15-40 seconds.Aluminium cover with window.Chamber dimensions: 2x 450x580xh235 mm.Working height 900 mm.4 sealing bars (2 per chamber).Digital control panel with 10 programs, analog display.On request: inclined plate for liquid products, gas injection system "nitrogen", Soft air: gradual vacuuming, ....Professional machines on pedestal.The vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent incomplete...
%
Vacuum pump capacity 100m3/h (Busch type).Cycle time 15-40 seconds.Stainless steel cover.Chamber dimensions: 2x 620x500xh240 mm (Sealing length: 4 x 620mm).Working height 900 mm.4 sealing bars (2 per chamber)Digital control panel with 10 programs, maintenance program and pump cleaning.Soft air: gradual vacuuming.On request: gas injection system "nitrogen", ....Professional machines on pedestals.Vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent...
%
Pompe à vide capacité 100m3/h(de type Busch).Durée du cycle 15-40 secondes.Couvercle en aluminium avec hublot de visualisation.Dimensions de la chambre : 2x 550x700xh235 mm (Longueur de soudure: 4 x 550mm).Hauteur de travail 900 mm.4 barres de soudure (2 par chambre).Panneau de commande digital avec 10 programmes, programme d'entretien et nettoyage de la pompe.Sur demande: plaque inclinée pour produits liquides, système injection de gaz "azote", Soft air: mise à vide graduelle,...
%
Vacuum pump capacity 160m3/h (Busch type).Cycle time 15-40 seconds.Stainless steel cover.Chamber dimensions: 2x 620x750xh210 mm (Sealing length: 4 x 620mm).Working height 900 mm.4 sealing bars (2 per chamber)Digital control panel with 10 programs, maintenance program and pump cleaning.Soft air: gradual vacuuming.On request: gas injection system "nitrogen", ....Professional machines on pedestals.Vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent...
%
Vacuum pump capacity 250m3/h (Busch type).Cycle time 15-30 seconds.Stainless steel cover.Chamber dimensions: 2x 840x830xh250 mm (Sealing length: 4 x 840mm).Working height 900 mm.4 sealing bars (2 per chamber)Digital control panel with 10 programs, maintenance program and pump cleaning.Soft air: gradual vacuuming.On request: gas injection system "nitrogen", ....Professional machines on pedestals.Vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent...
%
Vacuum pump capacity 250m3/h (Busch type).Cycle time 15-30 seconds.Stainless steel cover.Chamber dimensions: 2x 1100x730x230 mm (Sealing length: 4 x 1100mm).Working height 900 mm.4 sealing bars (2 per chamber)Digital control panel with 10 programs, maintenance program and pump cleaning.Soft air: gradual vacuuming.On request: gas injection system "nitrogen", ....Professional machines on pedestals.Vacuum is managed in % thanks to the integrated vacuum sensor, no more risk of inadvertent...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...