Grey color, door with magnetic closureRefrigeration by fluid "absorption" = ammonia
%
Inside volume 30 liters.Inside dimensions, 331x215xh405 mm. Delivered with 1 shelf, removable and adjustable in height.Bulging door, reversible, closing by magnetic seal.Closing with keys.Refrigeration by fluid absorption (ammoniac system), quiet working.Mechanical thermostat, T° +2° +12°.Evaporator placed in the "streamers" walls.Automatic defrosting, with auto-evaporation.Exterior design in lacquered sheet steel, color black.Interior design in white ABS "thermo- formatted".Polyurethane...
%
- Gray color, door with magnetic door lock- Cooling by liquid suction = ammonia system
%
Inside volume 40 liters.Inside dimensions, 331x245xh459 mm. Delivered with 2 shelves, removable and adjustable in height.Bulging door, reversible, closing by magnetic seal.Closing with keys.Refrigeration by fluid absorption (ammoniac system), quiet working. Mechanical thermostat, T° +2° +12°. Evaporator placed in the "streamers" walls.Automatic defrosting, with auto-evaporation.Exterior design in lacquered sheet steel, color black.Interior design in white ABS "thermo- formatted".Polyurethane...
%
Inside volume 50 liters.Inside dimensions, 331x245xh569 mm. Delivered with 2 shelves, removable and adjustable in height.Bulging door, reversible, closing by magnetic seal.Closing with keys.Refrigeration by fluid absorption (ammoniac system), quiet working.Mechanical thermostat, T° +2° +12°.Evaporator placed in the "streamers" walls.Automatic defrosting, with auto-evaporation.Exterior design in lacquered sheet steel, color black.Interior design in white ABS "thermo- formatted".Polyurethane...
%
Extra large doors GN 2/1, on each side.Standard equipment: 2 grids GN 2/1 (650x530mm).2 ventilated evaporators.4 adjustable feet in stainless steel.Monocoque designManufactured in stainless steel (food), inside AISI 304, outside AISI 441.Independent upper top (dismountable), stainless steel AISI 304.Stainless steel rack and slides (anti-tilting), allowing to place the grids as one pleases.Stamped interior bottom, rounded angles and corners (without roughness).Doors with ergonomic handle (no...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...