GN 1/1 inner tank, made in stainless steel, removable tank.Heating by gas, stainless steel burners placed under the tank.Tap gas control, lighter, stainless steel structure.Adjustable feet.Stainless steel frame.NB delievered without GN containers!
%
With frontal drainage tap.Designed in stainless steel.Stainless steel tank AISI 304, stamped GN 1/1 (for tray height 150 mm).Stainless steel shielded element heating, placed below the tank.On/Off switch, thermostat from 0° to 90°C and safety thermostat.Appliances are complied with the CE in force.NB: Delivered without GN trays.
%
4 mm vitro , useful surface 342x425 mm.Double coil 180 and 280 mm (with automatic selection according to the diameter of the pan).Function "Booster" total power (3600 W) across the double inductor.Regulation of 12 positions from 50 W to 3600 W.Black vitroceramic, high temperature, 100% waterproof."Built-In" casing in stainless steel AISI 304 (30/10th).Glass touch control panel (detects the presence of finger), manual power setting with On-Off button. 12 positions, 3 preset power buttons...
%
6 mm vitro, useful surface 342x425 mm.Coil 230 mm.Regulation of 12 positions from 100 W to 3600 W.Single-voltage 400/3N (not switchable).Black vitroceramic, high temperature, 100% waterproof."Built-In" casing in stainless steel AISI 304 (30/10th).Glass touch control panel (detects the presence of finger), manual power setting with On-Off button. 12 positions, 3 preset power buttons (6/10/12), timer 0-99 minutes, visual display and acoustic signals.Standart washable filter delivered.Important...
%
%
6 mm vitro, useful surface 342x425 mm.Coil 230 mm.Regulation of 12 positions from 100 W to 6000 W.Single-voltage 400/3N (not switchable).Black vitroceramic, high temperature, 100% waterproof."Built-In" casing in stainless steel AISI 304 (30/10th).Glass touch control panel (detects the presence of finger), manual power setting with On-Off button. 12 positions, 3 preset power buttons (6/10/12), timer 0-99 minutes, visual display and acoustic signals.Standart washable filter delivered.Important...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Burner in painted cast iron with brass crown with high heat conductibility (1x 7kW).Lighting by back-burner, thermocouple protection.Cast iron grid armature and more robust stainless steel structure (reinforced).Reduction grid for burner (stainless steel).Removable stainless steel bowl and burner for easy maintenance.Enamelled grill 350 x 290 mm.Manufactured in stainless steel.4 lower cylinders, adjustable.The device is built in compliance with the current CE standards.
%
Burner in painted cast iron with brass crown with high heat conductibility (1x 7kW and 1x 5kW).Lighting by back-burner, thermocouple protection.Cast iron grid armature and more robust stainless steel structure (reinforced).Reduction grid for burner (stainless steel).Removable stainless steel bowl and burner for easy maintenance.Enamelled grill 350 x 290 mm.Manufactured in stainless steel.4 lower cylinders, adjustable.The device is built in compliance with the current CE standards.
%
Burner in painted cast iron with brass crown with high heat conductibility (1x 7 kW, 1x 5 kW and 1x 7 kW).Lighting by back-burner, thermocouple protection.Cast iron grid armature and more robust stainless steel structure (reinforced).Reduction grid for burner (stainless steel).Removable stainless steel bowl and burner for easy maintenance.Enamelled grill 350 x 290 mm.Manufactured in stainless steel.4 lower cylinders, adjustable.The device is built in compliance with the current CE standards.
%