- Turns/minute : rpm 180.- Duration of the production cycle 120-150 sec.- Color BLACK.- Stainless steel undercarriage AISI 304.- Stainless steel tank AISI 304, 100% hygienic, without rough part and rounded edges. - Plexiglas see-through lid allowing a field of vision of the production, safety DIP switch.- Abrasive turning trays and walls also fitted with an abrasive tape (both are easily transportable for the cleaning, the operations don't require any specialized labor). - Digital control...
%
- Turns/minute: rpm 180.- Duration of the production cycle 150-180 sec.- Color BLACK.- Stainless steel undercarriage AISI 304.- Stainless steel tank AISI 304, 100% hygienic, without rough part and rounded edges. - Plexiglas see-through lid allowing a field of vision of the production, safety DIP switch.- Abrasive turning trays and walls also fitted with an abrasive tape (both are easily transportable for the cleaning, the operations don't require any specialized labor). - Digital control...
%
%
%
%
Tank diameter 600 mm, depth 420 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 600 mm, depth 540 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 760 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (25/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 960 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (30/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 1060 mm, depth 600 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (40/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 400 mm, depth 465 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (15/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick) Made of AISI 304 stainless steel, stainless steel base. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of 304 stainless steel, bottom made of...
%
Tank diameter 760 mm, depth 500 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (25/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 960, depth 500mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (30/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 600 mm, depth 420 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 600 mm, depth 540 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 760 mm, depth 500 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (25/10 mm thick) wall made of 304 stainless steel (20/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 960 mm, depth 500 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (30/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick).Deep-drawn"...
%
Tank diameter 1060 mm, depth 600 mm.Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (40/10 mm thick) wall made of 304 stainless steel (25/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (20/10 mm thick). Made of AISI 304 stainless steel, version on AISI 304 stainless steel columns (delivered with floor fixing kit). Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm...
%
Tank diameter 400 mm, depth 465 mm."Deep-drawn" tank, bottom made of polished AISI 316 stainless steel (20/10 mm thick) wall made of 304 stainless steel (15/10 mm thick). Indirect heating, double jacket made of 304 stainless steel (15/10 mm thick). Made of AISI 304 stainless steel, stainless steel base. Covering: made of AISI 304 stainless steel (10/10 mm thick). Work surface: made of AISI 304 stainless steel (15/10 mm thick)."Deep-drawn" tank wall made of 304 stainless steel, bottom made of...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...