- Flow of the cooker hood: 910 m³/h.- Manufactured in stainless steel 18/10 AISI 441.- Invisible sides in galvanized steel.- Outlet tap underneath the hood.
%
- Flow of the cooker hood: 1390 m³/h.- Manufactured in stainless steel 18/10 AISI 441.- Invisible sides in galvanized steel.- Outlet tap underneath the hood.
%
- Flow of the cooker hood: 1860 m³/h.- Manufactured in stainless steel 18/10 AISI 441.- Invisible sides in galvanized steel.- Outlet tap underneath the hood.
%
- Flow of the cooker hood: 2340 m³/h.- Manufactured in stainless steel 18/10 AISI 441.- Invisible sides in galvanized steel.- Outlet tap underneath the hood.
%
- Flow of the cooker hood: 2812 m³/h.- Manufactured in stainless steel 18/10 AISI 441.- Invisible sides in galvanized steel.- Outlet tap underneath the hood.
%
- Flow of the cooker hood: 3330 m³/h.- Manufactured in stainless steel 18/10 AISI 441.- Invisible sides in galvanized steel.- Outlet tap underneath the hood.
%
Flow of the cooker hood: 3762 m³/h. Manufactured in stainless steel 18/10 AISI 441.Invisible sides in galvanized steel.Outlet tap underneath the hood.
%
Capacity 10 levels GN 2/1 (or 20x GN 1/1).Upper part with stainless steel gallery on 3 sides. Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°, closing with automatic return, avoiding heat loss.Possibility of using GN 2/1 or GN 1/1 spacing 60 mm.Heating by resistances...
%
Capacity 20 GN 2/1 levels (or 40x GN 1/1). Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°, closing with automatic return, avoiding heat loss.Possibility of using GN 2/1 or GN 1/1 spacing 60 mm.Heating by resistances and pulsed air, homogeneity of the temperature...
%
Capacity 40 GN 2/1 levels (or 80x GN 1/1).SPECIAL BANQUETING: Standard 20 grids to optimize space inside the trollley. Up to eight (8) plates with a diameter of 300 mm can be stored per level, for a total of 160 plates. Construction in austenitic stainless steel (food).Walls and door made of double injected prey (high density CFC-free polyurethane).Door opening at 120°, with vertical latch and key lock, with a seal in the door frame, easily replaceable without tools.Hinges with stop at 100°,...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...