%
- Tank 306x510xh110 mm, superficie 15,8 dm2- Deep-drawn top thickness 15/10th - Stainless steel tank AISI 316 "COMPOUND", with high thermal conductivity - Plug and extension for discharge, supplied as standard - Electrical heating: Stainless steel armoured resistors, positioned under the tank, regulation from 120°C to 300°. - Safety device in case of overheating - Water protection degree IPX5 - Made of AISI 304 stainless steel, adjustable stainless steel feet - Appliances built in compliance...
%
Tank 306x510xh110 mm, superficie 15,8 dm2Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivityPlug and extension for discharge, supplied as standardElectrical heating: Stainless steel armoured resistors, positioned under the tank, regulation from 120°C to 300°.Safety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable stainless steel feetAppliances built in compliance with current standards (CE)
%
Tank dimensions 630x510xh110 mm, surface 32,1 dm2. Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivityPlug and extension for discharge, supplied as standardElectrical heating: Stainless steel armoured resistors, positioned under the tank, regulation from 120°C to 300°.Safety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable stainless steel feetAppliances built in compliance with current...
%
Tank dimensions 630x510xh110 mm, surface 32,1 dm2. Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivityPlug and extension for discharge, supplied as standardElectrical heating: Stainless steel armoured resistors, positioned under the tank, regulation from 120°C to 300°.Safety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable stainless steel feetAppliances built in compliance with current...
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
Tank dimensions 630x510xh110 mm, surface area 32.1 dm2. Made of AISI 304 stainless steel, deep-drawn "top" (20/10 mm), adjustable stainless steel feet (150-200 mm), waterproof IPX5Tank in AISI 316 "COMPOUND" stainless steel, with high thermal conductivity.Plug and extension for discharge, supplied as standard.Electric heating: stainless steel armoured resistors, positioned under the tank, regulation from 120 to 300°C.Safety device in case of overheating.Appliances built in compliance with...
%
Tank dimensions 630x510xh110 mm, surface area 32.1 dm2. Made of AISI 304 stainless steel, deep-drawn "top" (20/10 mm), adjustable stainless steel feet (150-200 mm), waterproof IPX5Tank in AISI 316 "COMPOUND" stainless steel, with high thermal conductivity.Plug and extension for discharge, supplied as standard.Electric heating: stainless steel armoured resistors, positioned under the tank, regulation from 120 to 300°C.Safety device in case of overheating.Appliances built in compliance with...
%
Tank dimensions 306x510xh110 mm, surface 15,8 dm2.Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivityPlug and extension for discharge, supplied as standardGas heating: stainless steel burners with stabilized flame, regulation 100 to 250°C, piezoelectric ignitionSafety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable stainless steel feetAppliances built in compliance with current standards...
%
Tank dimensions 630x510xh110 mm, surface 32,1 dm2.Deep-drawn top thickness 15/10thStainless steel tank AISI 316 "COMPOUND", with high thermal conductivityPlug and extension for discharge, supplied as standardGas heating: stainless steel burners with stabilized flame, regulation 100 to 250°C, piezoelectric ignitionSafety device in case of overheatingWater protection degree IPX5Made of AISI 304 stainless steel, adjustable stainless steel feetAppliances built in compliance with current standards...
%
Tank dimensions 630x510xh110 mm, surface area 32.1 dm2.Made of AISI 304 stainless steel, deep-drawn "top" (20/10 mm), adjustable stainless steel feet (150-200 mm), waterproof IPX5Tank in AISI 316 "COMPOUND" stainless steel, with high thermal conductivity.Plug and extension for discharge, supplied as standard.Gas heating: stainless steel burners with stabilized flame, regulation 100 to 250°C, piezoelectric ignition.Safety device in case of overheating.Appliances built in compliance with...