High version, easier loading / unloading of baskets,..."Double-walled" Standard version Load height 405 mmplate height 380 mm From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuousRotating wash and rinse arms (upper and lower), lower in stainless steelSelf-cleaning jetsTank (23 Lt., 2,1 kW) with rounded edges, "stamped" bottom"Stamped" double walled door, "removable" gasketRemovable control panelAutomatic filling of the tankCheck valveHot water rinse (2,5 Lt. water consumption...
%
Low version, installation option under sinks and cupboards etc...."Double-walled" VersionLoad height 405 mmPlate height 380 mm From 60 till 24 baskets/hour, cycles 60'' - 120'' - 150" or continuousRotating wash and rinse arms (upper and lower), lower in stainless steelSelf-cleaning jetsTank (23 Lt., 2,1 kW) with rounded edges, "stamped" bottom"Stamped" double walled door, "removable" gasketRemovable control panelAutomatic filling of the tankCheck valveHot water rinse (2,5 Lt. water...
%
Realisation "double walled". with thermic insulation.Watersoftener continuously, incorporated (WARNING: connection to cold water).Charging height diam. 465 mm.Standard rinsing pump (atmospheric boiler). Control panel at the top of the hood, digital display.Basket 600x500 mm, capacity 22 plates, dishes 600x400 (see accessories), beer baskets 600x400 to 135 Lt, always the possibility of using 500x500 mm baskets. 3 cycles: 60 '- 110' - 150 '' or continuous.Device opening and closing cover on...
%
Realization in "double walls" with thermal insulationIntegration of the "Green System H.R.S. Condenser-recovery of vapors, great energy saving (ATTENTION: connection to cold water)Continuous water softener, incorporated (ATTENTION: connection to cold water)Loading height 465 mmStandard flush pump (atmospheric boiler). Control panel on top of the cover, digital displayBasket 600x500 mm, capacity 22 plates, plates 600x400 (see accessory), beer baskets 600x400 up to 135 Lt, still possible to use...
%
%
%
%
%
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...