Delivered with 1 plate in stainless steel and 1 grill 460x340 mm.1 turbine "autoreverse".Cooking chamber: fully welded, fully waterproof, rounded corners and corners. Seal on the counter door, easily removable. Easily removable (75 mm) antitipper plate holder structure. Deflectors easily removable. Oura for condensate drainage.Motor(s) with turbine(s) (2800 rpm) "self-reversing" guarantee a homogeneous heat diffusion.Athermal door with double glazing (4 mm), hinged intermediate glass, easy...
%
Supplied with 1 grid 600x400 mm.2 "autoreverse" turbinesCooking chamber: fully welded, fully waterproof, rounded corners and corners. Seal on the counter door, easily removable. Easily removable (75 mm) antitipper plate holder structure. Deflectors easily removable. Oura for condensate drainage.Motor(s) with turbine(s) (2800 rpm) "self-reversing" guarantee a homogeneous heat diffusion.Athermal door with double glazing (4 mm), hinged intermediate glass, easy maintenance. Ergonomic and athermic...
%
- Supplied with 1 grid 600x400 mm. - 2 "autoreverse" turbines- Cooking chamber: fully welded, fully waterproof, rounded corners and corners. Seal on the counter door, easily removable. Easily removable (75 mm) antitipper plate holder structure. Deflectors easily removable. Oura for condensate drainage. - Motor(s) with turbine(s) (2800 rpm) "self-reversing" guarantee a homogeneous heat diffusion. - Athermal door with double glazing (4 mm), hinged intermediate glass, easy maintenance. Ergonomic...
%
Supplied with 1 grid 600x400 mm.2 "autoreverse" turbinesCooking chamber: fully welded, fully waterproof, rounded corners and corners. Seal on the counter door, easily removable. Easily removable (75 mm) antitipper plate holder structure. Deflectors easily removable. Oura for condensate drainage.Motor(s) with turbine(s) (2800 rpm) "self-reversing" guarantee a homogeneous heat diffusion.Athermal door with double glazing (4 mm), hinged intermediate glass, easy maintenance. Ergonomic and athermic...
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Delivered with one gridlle GN 1/12 fans "autoreverse"Inside and outside made off stainless steel AISI 430.Cooking area: fully welded, fully hermetic, rounded edges and angles. - Joint on the inner door, easily removable.Stamped bottom collects the condensate to the waste unit. Plate holder structure, easily removable (75 mm) anti toppling.Heat diffusers easily removable.Evacuation pipe for the condensate.Motors with "autoreverse" turbines (2800 t/mn) guarantee a perfect heat diffusion.Door:...
%
%
Sold with one gridlle GN 2/31 fan "autoreverse"Inside and outside made off stainless steel AISI 430.Cooking area: fully welded, fully hermetic, rounded edges and angles. - Joint on the inner door, easily removable.Stamped bottom collects the condensate to the waste unit. Plate holder structure, easily removable (75 mm) anti toppling.Heat diffusers easily removable.Evacuation pipe for the condensate.Motors with "autoreverse" turbines (2800 t/mn) guarantee a perfect heat diffusion.Door:...