Version for espresso coffee and American coffee (small lifting cup rest grill).Boiler capacity 11 litres.2 steam valves, tube and head steaming all stainless steel1 hot water outlet, electronic control, programmable.Supplied with 3 pouring spouts, 2x (2 cups) and 1x (1 cup) and "blind" filter for daily maintenance of the groups.Electronic machines with "volumetric" dosing unit, control keypad with backlit keys (double contact).Unit made of brass (chrome finish), heat guaranteed, with...
%
%
%
Version for espresso coffee and American coffee (small lifting cup rest grill).Boiler capacity 6,5 litres.1 steam tap, tube and head vaporizing all stainless steel.1 hot water tap.Supplied with 3 pouring spouts, 2x (2 cups) and 1x (1 cup) and "blind" filter for daily maintenance of the groups.Electronic machines with "volumetric" dosing unit, control keypad with backlit keys (double contact).Unit made of brass (chrome finish), heat guaranteed, with pre-infusion, solenoid valve for each...
%
Version for espresso coffee and American coffee (small lifting cup rest grill).Boiler capacity 6.5 litres.1 steam tap, tube and head vaporizing all stainless steel.1 hot water tap, with stainless steel tube.Supplied with 3 pouring spouts, 2x (2 cups) and 1x (1 cup) and "blind" filter for daily maintenance of the groups.Semi-automatic machines, On/Off switch.Unit made of brass (chrome finish), heat guaranteed, with pre-infusion, solenoid valve for each unit.Hot water tap, for tea, herbal teas,...
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...