- Air condenser.- Vertical turbine with automatic extraction, low maintenance and very easy to use.- Easy installation due to its compact size.- Minimum mixing capacity 1 liter and maximum 2 liters.- Noise level below 70 dB.- Cycle with time control or with temperature control.- Vertical cylinders-evaporators for a bigger surface of exchange.- Exclusive dispensing device.- Auto diagnostic system.- Cycle time: 10/20 min.- Hourly production: 12 liters.NB: mainly for cold work.
%
- Air condenser.- Vertical turbine with automatic extraction, low maintenance and very easy to use.- Easy installation due to its compact size.- Minimum mixing capacity 1 liter and maximum 2 liters.- Noise level below 70 dB.- Cycle with time control or with temperature control.- Vertical cylinders-evaporators for a bigger surface of exchange.- Exclusive dispensing device.- Auto diagnostic system.- Cycle time: 10/20 min.- Hourly production: 12 liters.NB: mainly for cold work.
%
Structure in AISI 304 stainless steel.Polycarbonate tank (capacity from 3 to 5.5 litres), with 2-part lid for easy filling, equipped with a "self-cleaning" metering tap.Vertical evaporator, made of AISI 304 stainless steelRefrigerant gas R290, vertical mixing system "exclusive patent" guaranteeing perfect homogeneity (without foam formation!).Very versatile, regulating the fineness of the "granita".Fully removable, making daily maintenance easier.Appliances built in compliance with the...
%
Structure in AISI 304 stainless steel.Polycarbonate tank (capacity from 3 to 5.5 litres), with 2-part lid for easy filling, equipped with a "self-cleaning" metering tap.Vertical evaporator, made of AISI 304 stainless steel,Refrigerant gas R290, vertical mixing system "exclusive patent" guaranteeing perfect homogeneity (without foam formation!).Very versatile, regulating the fineness of the "granita".Fully removable, making daily maintenance easier.Appliances built in compliance with the...
%
%
%
LED type light (patented)Possible to insert advertising images, protection made of transparent plexiglasProtected controls, with one inspection wicketPolycarbonate vats, ABS lid, with a measuring tap, entirely dismountable for an easier maintenance.Refrigeration evaporator in stainless steel AISI 304.Refrigerant gas R290Temperature maintenance device for night time.
%
LED type light (patented)Possible to insert advertising images, protection made of transparent plexiglasProtected controls, with one inspection wicketPolycarbonate vats, ABS lid, with a measuring tap, entirely dismountable for an easiermaintenance.Refrigeration evaporator in stainless steel AISI 304.Refrigerant gas R290Temperature maintenance device for night time.
%
LED type light (patented)Possible to insert advertising images, protection made of transparent plexiglasProtected controls, with one inspection wicketPolycarbonate vats, ABS lid, with a measuring tap, entirely dismountable for an easier maintenance.Refrigeration evaporator in stainless steel AISI 304.Refrigerant gas R290Temperature maintenance device for night time.
%
Cooling capacity rendered 633 (W/f) for chamber volume 3,0 m³ / 3000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 824 (W/f) for chamber volume 5,0 m³ / 5000 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are...
%
Cooling capacity rendered 1258 (W/f) for chamber volume 10,2 m³ / 10200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 1509 (W/f) for chamber volume 13,2 m³ / 13200 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity rendered 2313 (W/f) for chamber volume 27,8 m³ /27800 Lit. (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve.The low temperature units (HN) are supplied with a cable for the connection of the door resistor. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables...
%
Cooling capacity 2139 (W/f) for room volume 18,1 m³ / 18100 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard...
%
Cooling capacity 3490 (W/f) for room volume 34,3 m³ / 34300 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by thermostatic valve.Also equipped with a high pressure switch (fixed calibration) (C-PMAX-R). Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a...
%
Cooling capacity 981 (W/f) for room volume 6,2 m³ / 6200 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a high...
%
Cooling capacity 1800 (W/f) for room volume 14,9 m³ / 14900 Lit (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Bi-block" refrigeration units.Due to its design, the condensing unit is suitable for outdoor installation and can be placed anywhere, floor, ceiling, wall,...Delivered with 2 wall brackets as standard. Pipes (pre-loaded) and cables are supplied for connection within a radius of 5 meters (10 meters optional).All units are supplied as standard with a...
%
%