Base crossed with storage for plates and cutlery.Stainless steel posterns, roof with removable protections (condiments or dishes 190 mm) , anti-breath protection cristal "plexiglas", at each side, LED lighting.2 stainless steel tracks, 1 at each side (folding shelves, easy pass, standard doors, 0.8 m).Built-in compressor unit, climate class 4 (30°C & 55% RH)Evaporator "coil" drowned in the stainless steel tank.Ecological refrigerant R290 (CFC-free)Insulation made of expanded polyurethane,...
%
Base crossed with storage for plates and cutlery.Stainless steel posterns, roof with removable protections (condiments or dishes 190 mm) , anti-breath protection cristal "plexiglas", at each side, LED lighting.2 stainless steel tracks, 1 at each side (folding shelves, easy pass, standard doors, 0.8 m).Built-in compressor unit, climate class 4 (30°C & 55% RH)Evaporator "coil" drowned in the stainless steel tank.Ecological refrigerant R290 (CFC-free)Insulation made of expanded polyurethane,...
%
- Refrigerated version: "coil" evaporator immersed under the stainless steel tank, expanded polyurethane insulation, CFC-free. - Drain for condensate discharge. - Ecological refrigerant R134A (CFC-free). - U.H./Danfoss compressor, for ambient temperature (+32°C). - Electronic thermostat.- Wooden construction. - Through base for the storage of plates and cutlery. - Brushed stainless steel pots, roof with removable retainers (condiments or 190 mm plates), "tempered" glass breath guard on each...
%
Unit width 400 mm, small footprint.Cooling capacity 671 (W/f) for chamber volume 3,6 m³ / 3600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 817 (W/f) for chamber volume 4,8 m³ / 4800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Unit width 400 mm, small footprint.Cooling capacity 953 (W/f) for chamber volume 6,1 m³ / 6100 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The...
%
Cooling capacity 1577 (W/f) for chamber volume 16,3 m³ / 16300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 1914 (W/f) for chamber volume 19,4 m³ / 19400 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2343 (W/f) for chamber volume 29,2 m³ / 29200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity 2547 (W/f) for chamber volume 34,2 m³ / 34200 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped...
%
Cooling capacity rendered 1960 (W/f) for chamber volume 16,4 m³ / 16400 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Cooling capacity rendered 3389 (W/f) for chamber volume 37,6 m³ / 37600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice formation. Refrigerant gas...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 975 (W/f) for chamber volume 6 m³ / 6000 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent ice...
%
Unit width 400 mm, small footprint.Cooling capacity rendered 1302 (W/f) for chamber volume 10,6 m³ / 10600 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. "Overlapping" refrigeration units.Unit certified in climatic class 5 (40°C Temperature - 40% Humidity).All units are supplied as standard with a high pressure switch and KVL valve.Automatic hot gas defrost with self-evaporation and overflow.The evaporator drain pipe is equipped with a resistor to prevent...
%
Independent selection of the 3 quartz ramps with 3 tubes: function toaster or salamander, without pre-heating, high output (400 toasts/hour).2 grids with thermal handles (1 with stainless steel closing).Realization in stainless steel.Floor space 510x320 mm.Heating by infrared "quartz" tubes.Quartz ramp selector, timer 15 min. with continuous position, tensioning warning light, heating warning light.Protection grids of the "quartz" tubes, dismountable (exclusive patent).Removable lower...
%
Independent selection of the 2 quartz ramps with 3 tubes: function toaster or salamander, without pre-heating, high output (200 toasts/hour).2 grids with thermal handles.Realization in stainless steel.Floor space 510x320 mm.Heating by infrared "quartz" tubes.Quartz ramp selector, timer 15 min. with continuous position, tensioning warning light, heating warning light.Protection grids of the "quartz" tubes, dismountable (exclusive patent).Removable lower collection tank.Lift-off of the back...