Created for displays VBE-211.On the service side, adjustable intermediary shelf. Grommet.Construction in stainless steel, castors with brakes.sliding doors.
%
%
Capacity 2x GN 1/1 height 150 mm.Made of : stainless steel security window rounded, plexi sliding doors operators sideFlexibility: the hologeen lamp and lighting on the upper part, associated with the bain-mariekeeps the food on temperatures level desired, respecting all hygienic rules.Drop in: stainless steel container to be insert, fitted with edgeBin capacity: 2x GN 1/1 or 3x GN 1/1, max height 150 mm (delivered without bin)Electrical heating: warmed up trough armoured elements in...
%
Capacity 3x GN 1/1 height 150 mm.Made of: stainless steel security window rounded, plexi sliding doors operators side.Flexibility: the hologeen lamp and lighting on the upper part, associated with the bain-mariekeeps the food on temperatures level desired, respecting all hygienic rules.Drop in: stainless steel container to be insert, fitted with edgesBin capacity: 2x GN 1/1 or 3x GN 1/1, max height 150 mm (delivered without bin).Electrical heating: warmed up trough armoured elements in...
%
Cooling capacity 586 (W/f) for chamber volume 2,8 m³ / 2800 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 895 (W/f) for chamber volume 5,7 m³ / 5700 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1058 (W/f) for chamber volume 7,6 m³ / 7600 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 1733 (W/f) for chamber volume 17,3 m³ / 17300 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity 2463 (W/f) for chamber volume 30,5 m³ / 30500 Lit (T° internal -20° C & T° external +32° C).Refrigerant expansion by thermostatic valve. Supplied with a cable for the connection of the door heater. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with...
%
Cooling capacity rendered 1881 (W/f) for chamber volume 15,7 m³ / 15700 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 2961 (W/f) for chamber volume 28,2 m³ / 28200 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation,...
%
Cooling capacity rendered 1072 (W/f) for chamber volume 7,1 m³ / 7100 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
Cooling capacity rendered 1288 (W/f) for chamber volume 9,5 m³ / 9500 Lit. (T° internal 0° C & T° external +32° C).Refrigerant expansion by capillary. Ceiling" refrigeration units.All units are supplied as standard with a high pressure switch and KVL valve as well as cables for door and light micro-switches.Separate control panel, connected to the unit by a 5m cable, control of the functions by microprocessor with touch-sensitive keys.Automatic hot gas defrosting with self-evaporation, as...
%
2 pins provided, each for 3 chickens.Version to put.Made of AISI 304 stainless steelCapacity 3 chickens per pin, all pins are supplied as standard with 2 end and 2 central peaks, as well as a hook for handlingElectric heating: by "glass-ceramic" heaters, uniform heat source.Single engineChain driveIndependent regulation of each pinAll our models are equipped with "safety" windows on the front, magnetic closing, athermic handles.Lighting, by halogen lamps.Removable grease collection...
%
2 pins provided, each for 3 chickens.Version to put.Made of AISI 304 stainless steelCapacity 3 chickens per pin, all pins are supplied as standard with 2 end and 2 central peaks, as well as a hook for handlingGas heating: by ceramic radiators, equipped with safety thermocouple, removable heat deflectors.Single engineChain driveIndependent regulation of each pinAll our models are equipped with "safety" windows on the front, magnetic closing, athermic handles.Lighting, by halogen...